Needle-tissue interaction modeling using ultrasound-based motion estimation: Phantom study
Authors:
- Xu WenXWXu Wen
- Reza Zahiri-AzarRZReza Zahiri-Azar
- Maud MarchalMMMaud Marchal
- Septimiu E. SalcudeanSSSeptimiu E. Salcudean
- 6 January 2008
- journal article
- research article
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 13 (5) , 265-280
Abstract
Needle insertion simulators find use in a number of medical interventions, such as prostate brachytherapy. A needle insertion simulator has three main components: the needle model, the tissue model, and the model of interaction between the needle and the tissue. In this paper, a new methodology is introduced for the joint modeling of tissue and needle-tissue interactions. The approach consists of the measurement of tissue motion using ultrasound, and of the needle position and base force. Tissue motion is determined using a correlation-based algorithm that processes the ultrasound radiofrequency data. The tissue elastic parameters and the parameters of the tissue-needle interaction model are determined by using numerical optimization to match the response of the needle insertion model to the measured data. Phantom experiments were carried out in which a brachytherapy needle was inserted into a two-layer non-homogeneous phantom mimicking a prostate and its surrounding tissue. Experimental results show good agreement with the model obtained. In particular, the parameters of a three-parameter force model were identified for each layer of the phantom to fit the measured force to the simulated one. Also, the Young's modulus of each layer was identified to match the measured and simulated nodal axial displacements. This is the first report of the use of ultrasound radiofrequency data to characterize tissue motion during needle insertion. As the method is non-invasive and does not involve ionizing radiation, its application in patient studies is feasible.Keywords
This publication has 20 references indexed in Scilit:
- An improved needle steering model with online parameter estimatorInternational Journal of Computer Assisted Radiology and Surgery, 2006
- A new robotic needle insertion method to minimise attendant prostate motionRadiotherapy and Oncology, 2006
- 3D simulation of needle-tissue interaction with application to prostate brachytherapyComputer Aided Surgery, 2006
- Robotically assisted prostate brachytherapy with transrectal ultrasound guidance—Phantom experimentsBrachytherapy, 2006
- Measurement of prostate rotation during insertion of needles for brachytherapyRadiotherapy and Oncology, 2005
- Needle Steering and Motion Planning in Soft TissuesIEEE Transactions on Biomedical Engineering, 2005
- An ultrasound-driven needle-insertion robot for percutaneous cholecystostomyPhysics in Medicine & Biology, 2004
- Medical robotics in computer-integrated surgeryIEEE Transactions on Robotics and Automation, 2003
- Seed misplacement and stabilizing needles in transperineal permanent prostate implantsRadiotherapy and Oncology, 2000
- Dose effects of seeds placement deviations from pre-planned positions in ultrasound guided prostate implantsRadiotherapy and Oncology, 1994