Standard method for ultrasound imaging of coronary artery in children
Authors:
- 19 December 2010
- journal article
- research article
- Published by Wiley in Pediatrics International
- Vol. 52 (6) , 876-882
Abstract
The Child Coronary Arterial Diameter Reference Study Group of the Japan Kawasaki Disease Society recommends ultrasound imaging as the standard method for measuring the diameter of the coronary artery in children. The patient is examined in a supine or right decubitus position by using a sector probe (≥ 5 MHz). The coronary arterial diameter measured at the minimum gain setting is the distance between the internal echo edge and the internal echo edge. The diameter is measured during the early diastolic phase at the end of the T wave. The left main coronary artery and the proximal right coronary artery are approached from the precordial short axis at the level of the aortic valve. The proximal and mid-right coronary arteries are observed on the atrioventricular groove, anterior to the tricuspid valve ring. The right coronary artery of the acute margin of the heart runs along the right side of the tricuspid valve ring. The distal right coronary artery is observed on the posterior atrioventricular groove, and the posterior descending branch of the right coronary artery is observed on the posterior interventricular groove. The right coronary artery is also well observed from the right sternal border in the right decubitus position. Proximal and mid-anterior descending arteries are observed on the anterior interventricular groove. The proximal left circumflex coronary artery is observed in the atrioventricular groove, anterior to the mitral valve ring.Keywords
This publication has 14 references indexed in Scilit:
- Ultrasound settings significantly alter arterial lumen and wall thickness measurementsCardiovascular Ultrasound, 2008
- Methodological considerations of ultrasound measurement of carotid artery intima–media thickness and lumen diameterClinical Physiology and Functional Imaging, 2007
- Guidelines and Standards for Performance of a Pediatric Echocardiogram: A Report from the Task Force of the Pediatric Council of the American Society of EchocardiographyJournal of the American Society of Echocardiography, 2006
- Reproducibility of Ultrasonographically Determined Intima-Media Thickness Is Dependent on Arterial Wall ThicknessStroke, 1997
- Systolic Coronary Flow Reversal and Abnormal Diastolic Flow Patterns in Patients With Aortic Stenosis: Assessment With an Intracoronary Doppler CatheterJournal of the American Society of Echocardiography, 1993
- Noninvasive quantification of atherosclerotic lesions. Reproducibility of ultrasonographic measurement of arterial wall thickness and plaque size.Arteriosclerosis and Thrombosis: A Journal of Vascular Biology, 1992
- Distinguishing between anomalous origin of the left coronary artery from the pulmonary trunk and dilated cardiomyopathy: role of echocardiographic measurement of the right coronary artery diameter.Heart, 1989
- Resolution and accuracy in two dimensional echocardiographyThe American Journal of Cardiology, 1981
- Reliability and reproducibility of two dimensional echocardiographic measurement of the stenotic mitral valve orifice areaThe American Journal of Cardiology, 1979
- A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart AssociationCirculation, 1975