Ppb-Level Ammonia Detection by Exfoliated WS2 Based Chemiresistive Sensors for Breath Analysis
- 1 October 2018
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Abstract
The sensing behavior of as-synthesized and annealed WS2 nanosheets towards Ammonia has been demonstrated in this study. The nanosheets were synthesized using liquid-phase exfoliation technique It was observed that sonication time affects the ammonia sensing performance and 3-6 hours sonicated samples showed good sensing performances with 5 hours sonicated sample showing optimal performance. The as-synthesized nanosheets based chemiresistive sensors showed reasonable response towards ammonia in the concentration range of 300 ppb (3.8%) to 3 ppm (79.10%) at an optimum temperature of 250°C. The response and recovery time were found to be 67 sand 87 s respectively. These samples were further annealed for two hours in itrogen ambient and this significantly enhanced the response by an order of magnitude for the highest concentration of 3 ppm, i.e. from 79.1% to 1805%. The response and recovery time were found to be 125 sand 59 s. Though the linearity of the device response is affected by the annealing process, it enables the sensor to push the lowest limit of detection down to 50 ppb. A plausible mechanism has also been proposed for this sensor.Keywords
Funding Information
- Ministry of Education, India
- Science and Engineering Research Board
This publication has 21 references indexed in Scilit:
- Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurementsJournal of Breath Research, 2013
- Identification of individual and few layers of WS2 using Raman SpectroscopyScientific Reports, 2013
- High‐Concentration Aqueous Dispersions of MoS2Advanced Functional Materials, 2013
- Thickness and strain effects on electronic structures of transition metal dichalcogenides: 2H-MX2 semiconductors (M = Mo, W; X = S, Se, Te)Physical Review B, 2012
- An Official ATS Clinical Practice Guideline: Interpretation of Exhaled Nitric Oxide Levels (FeNO) for Clinical ApplicationsYearbook of Pulmonary Disease, 2012
- New Model for a Pd-Doped SnO2-Based CO Gas Sensor and Catalyst Studied by Online in-Situ X-ray Photoelectron SpectroscopyThe Journal of Physical Chemistry C, 2011
- How to Interpret Hydrogen Breath TestsJournal of Neurogastroenterology and Motility, 2011
- Micromachined NH3 Gas Sensor with ppb-level Sensitivity Based on WO3 Nanoparticles ThinfilmProcedia Engineering, 2011
- Ultrasensitive NH3 Gas Sensor from Polyaniline Nanograin Enchased TiO2 FibersThe Journal of Physical Chemistry C, 2010
- Ammonia sensors and their applications—a reviewSensors and Actuators B: Chemical, 2005