Influence of Exposure Parameters and Implant Position in Peri-Implant Bone Assessment in CBCT Images: An In Vitro Study
Open Access
- 2 July 2022
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (13) , 3846
Abstract
The aim of this study was to assess the impact of dimensional distortion and its changes with modification of exposure setting parameters on the measurements of peri-implant bone margin. Ten titanium dental implants (InKone Primo, Global D, Paris, France) were placed in two prepared bovine ribs. Two bone models and an implant-with-transfer model were scanned with 3shape E4 (3shape, Copenhagen, Denmark) laboratory scanner. Cone beam computed tomography (CBCT) images of two bone models were taken with different values of voltage (60, 70, 80, 90 kV), tube current (4, 10 mA) and voxel size (200, 300 µm). All the data were superimposed using planning software, and the measurements of buccal bone thickness in two selected regions were performed both using CBCT and scan cross-sections. The mean squared error (MSE) being the squared differences between measurements was used in the accuracy assessment of the CBCT device. A one-way ANOVA revealed significant differences between voltage and MSE (p = 0.044), as well as implant position and MSE (p = 0.005). The distortions of measurements depend on bone margin thickness, and the higher the distance to measure, the higher the error. Accurate measurements of buccal bone thickness (MSE below 0.25) were achieved with voltage values of 70, 80, and 90 kV.Keywords
This publication has 40 references indexed in Scilit:
- Accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomographyClinical Oral Investigations, 2012
- Accuracy of cone-beam computed tomography to assess the configuration and extent of ligature-induced peri-implantitis defects. A pilot studyOral and Maxillofacial Surgery, 2012
- 10‐Year Survival and Success Rates of 511 Titanium Implants with a Sandblasted and Acid‐Etched Surface: A Retrospective Study in 303 Partially Edentulous PatientsClinical Implant Dentistry and Related Research, 2012
- Accuracy of measuring the cortical bone thickness adjacent to dental implants using cone beam computed tomographyClinical Oral Implants Research, 2010
- On cone‐beam computed tomography artifacts induced by titanium implantsClinical Oral Implants Research, 2009
- Failure Strength of 2.0 Locking Versus 2.0 Conventional Synthes Mandibular Plates: A Laboratory ModelJournal of Oral and Maxillofacial Surgery, 2006
- Probe penetration in periodontal and peri‐implant tissues: An experimental study in the beagle dogClinical Oral Implants Research, 2006
- Ridge alterations following implant placement in fresh extraction sockets: an experimental study in the dogJournal of Clinical Periodontology, 2005
- An in vitro evaluation of miniplate fixation techniques for fractures of the atrophic edentulous mandibleInternational Journal of Oral and Maxillofacial Surgery, 2005
- Substitutes for human cadaveric bone in maxillofacial rigid fixation researchOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2000