Abstract
Background The strategy of cardiac implantable electronic device (CIED) implantations performed as day-case admissions has gained a wider acceptance overtime; however, data on safety are still limited. This study aims to investigate the safety of a same-day discharge protocol introduced in our hospital for the postprocedural management of patients undergoing CIED implantation. Methods Α prospective, non-interventional, non-randomised study performed in a single high-volume implanting centre for a 16-month period (March 2020 to June 2021). At total of 821 of 965 (85.1%) patients scheduled for elective CIED implantation were considered to be eligible for inclusion in the Short-stay Device Management Protocol. These patients were compared with a historical group of 932 patients, meeting the same inclusion criteria. Results Procedure was successful in 812 patients (98.9%), committed to same-day discharge versus 921 of 932 patients (98.8%) admitted for overnight stay (p = 0.87). Overall, 90-day complication rate was comparable in both groups (4.14% vs 4.07%, p = 0.95), as was major (1.46% vs. 1.82%, p = 0.55) and minor (2.67% vs. 2.25%, p = 0.64) complication rates. The composite early post-procedural complication rates and late post-procedural complication rates were comparable among groups (0.97 vs 1.18%, p = 0.70 and 0.73% vs 0.64%, p = 0.83, respectively). Six hundred sixty-seven patients (84%) preferred the same-day discharge strategy. Finally, a reduction of 792 bed-days was recorded, resulting in possible financial Health System benefits. Conclusions Same-day discharge is feasible and safe in the majority of patients referred for CIED implantation. Additionally, same-day discharge is preferred by patients and may reduce procedure-related costs due to significant bed-day reductions.Keywords
This publication has 29 references indexed in Scilit:
- Feasibility and Safety of Same‐Day Discharge after Implantable Cardioverter Defibrillator Placement for Primary PreventionPacing and Clinical Electrophysiology, 2013
- Trends in Permanent Pacemaker Implantation in the United States From 1993 to 2009JACC, 2012
- Feasibility of Early Discharge After Implantable Cardioverter‐Defibrillator ProceduresJournal of Cardiovascular Electrophysiology, 2012
- Incidence and predictors of short- and long-term complications in pacemaker therapy: The FOLLOWPACE studyHeart Rhythm, 2012
- Implantation-Related Complications of Implantable Cardioverter-Defibrillators and Cardiac Resynchronization Therapy DevicesJACC, 2011
- Infection after pacemaker implantation: infection rates and risk factors associated with infection in a population-based cohort study of 46299 consecutive patientsEuropean Heart Journal, 2011
- Complication Rates Associated With Pacemaker or Implantable Cardioverter-Defibrillator Generator Replacements and Upgrade ProceduresCirculation, 2010
- Risk Factors Related to Infections of Implanted Pacemakers and Cardioverter-DefibrillatorsCirculation, 2007
- Early mobilization after pacemaker implantationJournal of Cardiovascular Medicine, 2006
- Day Case Permanent PacingPacing and Clinical Electrophysiology, 1991