Pumping O2 with no N2: An Overview of Hollow Fiber Membrane Oxygenators with Integrated Arterial Filters
Authors:
- 22 January 2020
- journal article
- review article
- Published by Bentham Science Publishers Ltd. in Current Topics in Medicinal Chemistry
- Vol. 20 (1) , 78-85
Abstract
The advancement of cardiac surgery benefits from the continual technological progress of cardiopulmonary bypass (CPB). Every improvement in the CPB technology requires further clinical and laboratory tests to prove its safety and effectiveness before it can be widely used in clinical practice. In order to reduce the priming volume and eliminate a separate arterial filter in the CPB circuit, several manufacturers developed novel hollow-fiber membrane oxygenators with integrated arterial filters (IAF). Clinical and experimental studies demonstrated that an oxygenator with IAF could reduce total priming volume, blood donor exposure and gaseous microemboli delivery to the patient. It can be easily set up and managed, simplifying the CPB circuit without sacrificing safety. An oxygenator with IAF is expected to be more beneficial to the patients with low body weight and when using a minimized extracorporeal circulation system. The aim of this review manuscript was to discuss briefly the concept of integration, the current oxygenators with IAF, and the in-vitro / in-vivo performance of the oxygenators with IAF.Keywords
This publication has 89 references indexed in Scilit:
- Evaluation of the Maquet Neonatal and Pediatric Quadrox I with an integrated arterial line filter during cardiopulmonary bypassPerfusion, 2012
- Evaluation of Quadrox-i and Capiox FX neonatal oxygenators with integrated arterial filters in eliminating gaseous microemboli and retaining hemodynamic properties during simulated cardiopulmonary bypassPerfusion, 2012
- The Aachen MiniHLM—A Miniaturized Heart‐Lung Machine for Neonates With an Integrated Rotary Blood PumpArtificial Organs, 2010
- Evaluation of the Quadrox-I neonatal oxygenator with an integrated arterial filterPerfusion, 2010
- Extracorporeal bubbles: a word of cautionInteractive CardioVascular and Thoracic Surgery, 2010
- The Capability of Trapping Gaseous Microemboli of Two Pediatric Arterial Filters With Pulsatile and NonPulsatile Flow in a Simulated Infant CPB ModelASAIO Journal, 2008
- Residual air in the venous cannula increases cerebral embolization at the onset of cardiopulmonary bypassEuropean Journal of Cardio-Thoracic Surgery, 2006
- Consensus on Microembolus Detection by TCDStroke, 1998
- Bigated Transcranial Doppler for the Detection of Clinically Silent Circulating Emboli in Normal Persons and Patients With Prosthetic Cardiac ValvesStroke, 1997
- Filtration in cardiopulmonary bypass: past, present and futurePerfusion, 1988