Optic nerve head changes in early glaucoma: a comparison between stereophotography and Heidelberg retina tomography
- 13 February 2009
- journal article
- research article
- Published by Springer Nature in Eye
- Vol. 24 (1) , 123-130
Abstract
To evaluate and compare the diagnostic accuracy of the Heidelberg retina tomograph (HRT) version 3 with that of glaucoma specialists using stereophotography in discriminating between normal eyes and patients with early glaucomatous visual field loss. A total of 105 eyes of 105 individuals were prospectively and consecutively recruited. The sample comprised 51 normal and 54 early glaucomatous eyes, as defined by intraocular pressure and standard automated perimetry results, regardless of optic disc appearance. Receiver operating characteristic (ROC) curves were plotted for the HRT3 parameters and a linear discriminant function (LDF) developed in our hospital. Best sensitivity–specificity pairs were compared between the HRT3 parameters, with the highest areas under the ROC curve (AUCs) and evaluation of optic disc stereophotographs. Agreement between methods for measuring vertical cup-to-disc ratio was evaluated with the Bland–Altman plot. The average visual field mean deviation was -2.90 dB. The HRT3 parameters with the largest AUCs were our LDF (0.900), rim volume (0.883), and vertical cup/disk ratio (0.880), with no significant differences between these parameters. Sensitivity–specificity pairs were 79.6–100% (clinical evaluation), 83.3–86.3% (our LDF), 64.8–96.1% (final glaucoma probability score), and 68.5–90.2% (global Moorfields regression analysis). The diagnostic accuracy for differentiating normal eyes from those with early visual field defects was similar between clinical evaluation of the optic disc and evaluation with the HRT3. The use of our LDF increased the sensitivity–specificity balance with respect to the HRT-provided parameters. The diagnostic accuracy of the HRT classifications was comparable to that of an experienced glaucoma specialist.Keywords
This publication has 34 references indexed in Scilit:
- Diagnostic Ability of Heidelberg Retina Tomograph 3 ClassificationsOphthalmology, 2007
- Automated Analysis of Heidelberg Retina Tomograph Optic Disc Images by Glaucoma Probability ScoreInvestigative Ophthalmology & Visual Science, 2006
- The Quality of Reporting of Diagnostic Accuracy Studies in Glaucoma Using the Heidelberg Retina TomographInvestigative Ophthalmology & Visual Science, 2006
- Comparison of the GDx VCC Scanning Laser Polarimeter, HRT II ConfocalScanning Laser Ophthalmoscope, and Stratus OCT Optical Coherence Tomographfor the Detection of GlaucomaArchives of Ophthalmology (1950), 2004
- Neuronal death in glaucomaProgress in Retinal and Eye Research, 1999
- Identification of early glaucoma cases with the scanning laser ophthalmoscope11The authors have no proprietary interest in the development or marketing of this or a competing instrument.Ophthalmology, 1998
- The Effect of Optic Disc Size on Diagnostic Precision with the Heidelberg Retina TomographOphthalmology, 1997
- The Lens Opacities Classification System IIIArchives of Ophthalmology (1950), 1993
- Test-Retest Variability in Glaucomatous Visual FieldsAmerican Journal of Ophthalmology, 1989
- Optic Disc Parameters and Onset of Glaucomatous Field LossArchives of Ophthalmology (1950), 1979