Estimation of effective doses to adult and pediatric patients from multislice computed tomography: A method based on energy imparted
Authors:
- John DamilakisJDJohn Damilakis
- Kostas PerisinakisKPKostas Perisinakis
- Antonis TzedakisATAntonis Tzedakis
- Apostolos KarantanasAKApostolos Karantanas
- Nicholas GourtsoyiannisNGNicholas Gourtsoyiannis
- 26 September 2006
- journal article
- Published by Wiley in Medical Physics
- Vol. 33 (10) , 3846-3856
Abstract
The purpose of this study is to provide a method and required data for the estimation of effective dose (E) values to adult and pediatric patients from computed tomography (CT) scans of the head, chest abdomen, and pelvis, performed on multi-slice scanners. Mean section radiation dose (dm) to cylindrical water phantoms of varying radius normalized over CT dose index free-in-air (CTDIF) were calculated for the head and body scanning modes of a multislice scanner with use of Monte Carlo techniques. Patients were modeled as equivalent water phantoms and the energy imparted (epsilon) to simulated pediatric and adult patients was calculated on the basis of measured CTDI(F) values. Body region specific energy imparted to effective dose conversion coefficients (E/epsilon) for adult male and female patients were generated from previous data. Effective doses to patients aged newborn to adult were derived for all available helical and axial beam collimations, taking into account age specific patient mass and scanning length. Depending on high voltage, body region, and patient sex, E/epsilon values ranged from 0.008 mSv/mJ for head scans to 0.024 mSv/mJ for chest scans. When scanned with the same technique factors as the adults, pediatric patients absorb as little as 5% of the energy imparted to adults, but corresponding effective dose values are up to a factor of 1.6 higher. On average, pediatric patients absorb 44% less energy per examination but have a 24% higher effective dose, compared with adults. In clinical practice, effective dose values to pediatric patients are 2.5 to 10 times lower than in adults due to the adaptation of tube current. A method is provided for the calculation of effective dose to adult and pediatric patients on the basis of individual patient characteristics such as sex, mass, dimensions, and density of imaged anatomy, and the technical features of modern multislice scanners. It allows the optimum selection of scanning parameters regarding patient doses at CT.Keywords
This publication has 20 references indexed in Scilit:
- Dose Reduction in Pediatric CT: A Rational ApproachRadiology, 2003
- AAPM/RSNA Physics Tutorial for Residents: Topics in CTRadioGraphics, 2002
- CT Colonography: Single- versus Multi–Detector Row ImagingRadiology, 2001
- Radiation doses to infants and adults undergoing head CT examinationsMedical Physics, 2001
- Managing patient dose in computed tomographyAnnals of the ICRP, 2000
- CT scanning: patterns of use and doseJournal of Radiological Protection, 2000
- Technique Factors and Image Quality as Functions of Patient Weight at Abdominal CTRadiology, 2000
- Cardiac Imaging by Means of Electrocardiographically Gated Multisection Spiral CT: Initial ExperienceRadiology, 2000
- Technical advances in multi–slice spiral CTEuropean Journal of Radiology, 2000
- Radiation Effective Doses to Patients Undergoing Abdominal CT ExaminationsRadiology, 1999