P2B-1 Synthetic Aperture Focusing Applied to Imaging Using a Rotating Single Element Transducer
Authors:
- Jacob KortbekJKJacob Kortbek
- Jorgen Arendt JensenJJJorgen Arendt Jensen
- Kim Lokke GammelmarkKGKim Lokke Gammelmark
- 1 October 2007
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10510117,p. 1504-1507
Abstract
This paper applies the concept of virtual sources and mono-static synthetic aperture focusing (SAF) to 2-dimensional imaging with a single rotating mechanically focused concave element with the objective of improving lateral resolution and signal-to-noise ratio (SNR). The geometrical focal point of the concave element can be considered as a point source emitting a spherical wave in a limited angular region. The SAF can be formulated as creating a high resolution line as a sum over low resolution lines (LRL). A LRL is the contribution from a single emission. Simulation in Field II is based on moving the concave element of radius 2.5 mm along a circle of radius 10 mm. Elements with different concave curvatures are used to obtain geometrical focusing depths at 10 mm, 15 mm, and 20 mm. Point targets in the range from 5 mm to 65 mm are used as image objects. The high resolution images (HRI) are shown and the radial and angular resolution are extracted at -6 dB and -40 dB. The performance of the setup with a VS at 20 mm is superior to the other setups. Due to the rotation, the synthesized aperture only experiences a moderate expansion, which is not sufficient to reduce the extent of the wide point spread function of a single emission. The effect of SAF with focal depth at 20 mm is negligible, caused by the small number of LRL applied. The great profit of the SAF is the increase in SNR. For the setup with focal depth at 20 mm the SAF SNR gain is 11 dB. The SNR gain of a setup with a VS at radius 10 mm or 15 mm over conventional imaging with a VS at 20 mm, is also 11 dB.Keywords
This publication has 11 references indexed in Scilit:
- Effects Influencing Focusing in Synthetic Aperture Vector Flow ImagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2007
- A study of synthetic-aperture imaging with virtual source elements in B-mode ultrasound imaging systemsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2000
- Theoretical assessment of a synthetic aperture beamformer for real-time 3-D imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1999
- Real-time 3-D ultrasound imaging using sparse synthetic aperture beamformingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1998
- Synthetic aperture techniques with a virtual source elementIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1998
- A 100-MHz ultrasound imaging system for dermatologic and ophthalmologic diagnosticsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1996
- Synthetic aperture imaging for small scale systemsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1995
- Ultrasound synthetic aperture imaging: monostatic approachIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1994
- Efficient synthetic aperture imaging from a circular aperture with possible application to catheter-based imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1992
- Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducersIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1992