A novel three-dimensional echocardiographic method for device size selection in patients undergoing ASD trans-catheter closure
Open Access
- 31 December 2019
- journal article
- research article
- Published by Springer Nature in The Egyptian Heart Journal
- Vol. 72 (1) , 1-8
Abstract
Proper device size selection is a crucial step for successful ASD device closure. The current gold standard for device size selection is balloon sizing. Balloon sizing can be tedious, time consuming and increase fluoroscopy and procedure times as well as risk of complications. We aimed to establish a simple and accurate method for device size selection using three-dimensional echocardiographic interrogation of the ASD.This is a prospective observational study conducted over a period of 12 months. All patients underwent 2D TTE, three-dimensional echocardiographic assessment of the IAS and transesophageal echocardiogram. Comparison between echocardiographic variables was done using independent sample t test. Linear correlation was established between three dimensional echocardiographic variables and respective variables of device size and 2D TTE and TEE measurements. The study included 50 patients who underwent successful ASD device closure with properly sized device. There was no significant difference between 3D ASD maximum diameter and all diameters measured by TTE and TEE. There was a strong positive correlation between device size used for closure and both 3D measured ASD area (r = 0.907, P<0.0001) and 3D measured ASD circumference (r = 0.917, P<0.0001). Two regression equations were generated to determine proper device size where Device size = 10.8 + [3.95 x 3D ASD area] and Device size = [3.85 x 3D ASD circumference] -1.02 Three-dimensional echocardiogram can provide a simple and accurate method for device size selection in patients undergoing ASD device closure using either 3D derived ASD area or ASD circumferenceKeywords
This publication has 12 references indexed in Scilit:
- Efficacy of 3D transoesophageal echocardiography for transcatheter device closure of atrial septal defect without balloon sizingEuropean Heart Journal - Cardiovascular Imaging, 2017
- The relation between atrial septal defect shape, diameter, and area using three-dimensional transoesophageal echocardiography and balloon sizing during percutaneous closure in childrenEuropean Heart Journal - Cardiovascular Imaging, 2015
- A different view on predictors of pulmonary hypertension in secundum atrial septal defectInternational Journal of Cardiology, 2014
- Prospective Randomized Trial of Transthoracic Echocardiography Versus Transesophageal Echocardiography for Assessment and Guidance of Transcatheter Closure of Atrial Septal Defects in Children Using the Amplatzer Septal OccluderJACC: Cardiovascular Interventions, 2013
- Effect of Atrial Septal Defect Shape Evaluated Using Three-Dimensional Transesophageal Echocardiography on Size Measurements for Percutaneous ClosureJournal of the American Society of Echocardiography, 2012
- Percutaneous Atrial Septal Defect Closure in Infants and Toddlers: Predictors of SuccessPediatric Cardiology, 2012
- Three-dimensional echocardiography in congenital heart diseaseArchives of Cardiovascular Diseases, 2011
- Real-time three-dimensional echocardiography of congenital heart disease using a high frequency paediatric matrix transducer.European Heart Journal - Cardiovascular Imaging, 2007
- Early and late complications associated with transcatheter occlusion of secundum atrial septal defectJACC, 2002
- Influence of atrial septal defect anatomy in patient selection and assessment of closure with the Cardioseal device. A three-dimensional transoesophageal echocardiographic reconstructionEuropean Heart Journal, 2000