The effects of large signals on charge collection in radiation detectors: Application to amorphous selenium detectors
- 15 June 2006
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 99 (12) , 124501
Abstract
Analytical and numerical models for studying the effects of large signals on charge collection efficiency in radiation detectors are described by considering bimolecular recombination between drifting charge carriers, carrier trapping, and space charge effects. First, an analytical solution is obtained by assuming that the field remains relatively uniform. Then the continuity equations for both holes and electrons, and Poisson’s equation across the photoconductor for a short pulse irradiation are simultaneously solved by the finite difference method, without any assumptions. There is a very good agreement between the approximate analytical and numerical solutions for the charge collection efficiency. The numerical results are also compared with Monte Carlo simulations of carrier transport. The charge collection efficiency model is applied to amorphous selenium x-ray image detectors. The bimolecular-recombination-limited charge collection efficiency depends on the total photogenerated carrier density rather than on its spatial distribution. It is found that the recombination plays practically no role up to the total instantaneous carrier generation of at the applied electric field of . The effect of recombination on charge collection increases with decreasing applied electric field strength. For high carrier generation (e.g., of for an applied field of ), the electric field distributions vary widely across the photoconductor thickness during the travel of charge carriers towards the electrodes. However, the effect of bimolecular recombination on charge collection efficiency is almost independent of bias polarity and the field distribution. The numerical results are also compared with recent experimental data available in the literature.
Keywords
This publication has 24 references indexed in Scilit:
- Bimolecular Recombination Coefficient as a Sensitive Testing Parameter for Low-Mobility Solar-Cell MaterialsPhysical Review Letters, 2005
- Dependence of x-ray sensitivity of direct conversion x-ray detectors on x-ray exposure and exposure history2004
- Evaluation of the imaging properties of an amorphous selenium‐based flat panel detector for digital fluoroscopyMedical Physics, 2004
- X-ray detector with on-pixel amplification for large area diagnostic medical imagingIEE Proceedings - Circuits, Devices and Systems, 2003
- DQE of photoconductive x-ray image detectors: application to a-SeJournal of Physics D: Applied Physics, 2002
- Charge collection and absorption-limited sensitivity of x-ray photoconductors: Applications to a-Se and HgI2Applied Physics Letters, 2002
- X-ray sensitivity of photoconductors: application to stabilized a-SeJournal of Physics D: Applied Physics, 2000
- Direct selenium x-ray detector for fluoroscopy, R&F, and radiography2000
- Study of the charge collection efficiency of CdZnTe radiation detectorsJournal of Electronic Materials, 1996
- Bulk recombination of charge carriers in polymer films: Poly-N-vinylcarbazole complexed with trinitrofluorenoneThe Journal of Chemical Physics, 1973