Computer-assisted unicompartmental knee arthroplasty using dedicated software versus a conventional technique
- 5 December 2013
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 38 (2) , 457-463
Abstract
The aim of this study was to retrospectively compare the results of two matched-paired groups of patients who had undergone a medial unicompartmental knee arthroplasty (UKA) performed using either a conventional or a non-image-guided navigation technique specifically designed for unicompartmental prosthesis implantation. Thirty-one patients with isolated medial-compartment knee arthritis who underwent an isolated navigated UKA were included in the study (group A) and matched with patients who had undergone a conventional medial UKA (group B). The same inclusion criteria were used for both groups. At a minimum of six months, all patients were clinically assessed using the Knee Society Score (KSS) and the Western Ontario and McMaster Osteoarthritis Index (WOMAC) index. Radiographically, the frontal-femoral-component angle, the frontal-tibial-component angle, the hip-knee-ankle angle and the sagittal orientation of components (slopes) were evaluated. Complications related to the implantation technique, length of hospital stay and surgical time were compared. At the latest follow-up, no statistically significant differences were seen in the KSS, function scores and WOMAC index between groups. Patients in group B had a statistically significant shorter mean surgical time. Tibial coronal and sagittal alignments were statistically better in the navigated group, with five cases of outliers in the conventional alignment technique group. Postoperative mechanical axis was statistically better aligned in the navigated group, with two cases of overcorrection from varus to valgus in group B. No differences in length of hospital stay or complications related to implantation technique were seen between groups. This study shows that a specifically designed UKA-dedicated navigation system results in better implant alignment in UKA surgery. Whether this improved alignment results in better clinical results in the long term has yet to be proven.Keywords
This publication has 32 references indexed in Scilit:
- The National Joint Registry of England and WalesOrthopedics, 2011
- Computer Assisted Navigation in Knee ArthroplastyClinics in Orthopedic Surgery, 2011
- Unicondylar knee arthroplasty in the UK National Health Service: An analysis of candidacy, outcome and cost efficacyThe Knee, 2009
- Long-term clinical results of the Oxford medial unicompartmental knee arthroplastyInternational Orthopaedics, 2009
- Unicompartmental or total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2009
- Navigated Shorter Incision or Smaller Implant in Knee Arthritis?Clinical Orthopaedics and Related Research, 2007
- Unicompartmental versus computer-assisted total knee replacement for medial compartment knee arthritis: a matched paired studyInternational Orthopaedics, 2006
- Limb alignment in computer-assisted minimally-invasive unicompartmental knee replacementThe Journal of Bone and Joint Surgery. British volume, 2006
- Results of Unicompartmental Knee Arthroplasty at a Minimum of Ten Years of Follow-upJournal of Bone and Joint Surgery, 2005
- Unicompartmental Arthroplasty of the KneeClinical Orthopaedics and Related Research, 1987