Six Sigma-Based Frequency Response Analysis for Power Transformer Winding Deformation
Open Access
- 3 April 2025
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 15 (7) , 3951
Abstract
Winding deformities in distribution transformers pose significant risks to operational reliability and system safety. Frequency response analysis (FRA) is a well-established technique for identifying mechanical faults; however, its diagnostic reliability is hindered by subjectivity in interpreting response signatures. This study proposes a novel diagnostic technique, termed FRA6σ, which integrates Six Sigma (6σ) statistical tools with FRA to enable objective fault detection. The methodology employs control charts ( chart, -chart) to monitor deviations from baseline signatures and utilizes process capability indices ( and ) to quantify the severity of deviations. Three transformer cases were evaluated across five defined frequency regions (10 Hz to 2 MHz), each associated with distinct physical fault types. The FRA6σ approach successfully identified early-stage faults across all cases. In one instance, axial and radial winding deformation was detected with a of 1.0 and corresponding range chart violations, preceding any visible damage. Another case revealed inter-turn insulation degradation in the 100 kHz–1 MHz band with values below 0.9, prompting immediate intervention. Compared to traditional FRA interpretation, the proposed method improved diagnostic sensitivity by 31.25% and enabled fault detection earlier based on retrospective physical inspection benchmarks. The integration of Six Sigma with FRA provides a structured, quantifiable, and repeatable approach to transformer fault diagnostics. FRA6σ enhances early detection of winding deformities and dielectric issues, offering a robust alternative to subjective analysis and supporting predictive maintenance strategies in power systems.
Keywords
This publication has 61 references indexed in Scilit:
- Low‐frequency noise removal and acoustic spectral distribution assessment method for high‐voltage power transformers with varying service lifetimesIET Electric Power Applications, 2025
- Tasks and Main Methods of Statistical Diagnostics of Electric Power Equipment2024
- Frequency Response Analysis: An Enabling Technology to Detect Internal Faults within Critical Electric AssetsApplied Sciences, 2022
- Application of Frequency Response Analysis Method to Detect Short-Circuit Faults in Three-Phase Induction MotorsApplied Sciences, 2022
- Lean Six Sigma2021
- Application of Frequency Response Analysis Technique to Detect Transformer Tap Changer FaultsApplied Sciences, 2021
- Interpretation of Frequency Response Analysis for Fault Detection in Power TransformersApplied Sciences, 2021
- Transformer frequency response: a new technique to analyze and distinguish the low-frequency band in the frequency response analysis spectrumIEEE Electrical Insulation Magazine, 2018
- Diagnostics of a Transformer's Active Part With Complementary FRA and VM MeasurementsIEEE Transactions on Power Delivery, 2013
- Diagnosing winding and core condition of power transformer by vibration signal analysis2012