Advantages of carbon fibre-reinforced polyetheretherketone over titanium implants in spine SBRT: a phantom evaluation
Open Access
- 21 July 2025
- journal article
- research article
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 48 (3) , 1325-1336
Abstract
This study evaluates the clinical feasibility of spine stereotactic body radiotherapy (SBRT) in the presence of titanium and carbon fibre-reinforced polyetheretherketone (CFR-PEEK) spinal implants using custom 3D-printed phantoms. The investigation focuses on the dosimetric accuracy, imaging challenges, and achievable localisation precision. Customised 3D-printed phantoms incorporating titanium and CFR-PEEK implants were computed tomography (CT) scanned, with and without metal artefact reduction (MAR) algorithms. Localisation accuracy was tested using Elekta XVI CBCT and Brainlab ExacTrac Dynamic. The dosimetric accuracy of the Monaco treatment planning system (TPS) was assessed under simple geometric conditions and for clinically realistic VMAT plans. Patient-specific quality assurance and phantom-based measurements using ionization chambers and radiochromic film were performed to evaluate delivered dose accuracy. Both Image Guided Radiotherapy (IGRT) systems achieved sub-millimetre localisation accuracy, with maximum deviations of 0.3 mm observed for titanium implants. The Monaco treatment planning system (TPS) demonstrated accurate dose modelling, with deviations < 1% for CFR-PEEK and < 2% for titanium implants in simple homogeneous arrangements. In complex VMAT plan deliveries, dosimetric measurements showed stronger agreement with TPS predictions for CFR-PEEK implants, with deviations < 3%. Titanium-based plans exhibited greater deviations, with localised dose discrepancies exceeding clinical tolerances of 5%. The application of MAR algorithms reduced these discrepancies to < 5%, ensuring clinically acceptable dosimetric accuracy. CFR-PEEK implants enhance clinical workflows due to reduced imaging artefacts and smoother dose distributions, making MAR corrections unnecessary. For titanium implants, MAR is essential to achieve clinically acceptable dosimetric accuracy, highlighting the robustness of CFR-PEEK for spine SBRT.Keywords
Funding Information
- University of Western Australia
This publication has 24 references indexed in Scilit:
- Efficacious patient‐specific QA for Vertebra SBRT using a high‐resolution detector array SRS MapCHECK: AAPM TG‐218 analysisJournal of Applied Clinical Medical Physics, 2024
- The dosimetric impact of titanium implants in spinal SBRT using four commercial treatment planning algorithmsJournal of Applied Clinical Medical Physics, 2023
- Investigation of the effects of spinal surgical implants on radiotherapy dosimetry: A study of 3D printed phantomsMedical Physics, 2021
- Measuring the dose in bone for spine stereotactic body radiotherapyPhysica Medica, 2021
- The dosimetric impact of stabilizing spinal implants in radiotherapy treatment planning with protons and photons: standard titanium alloy vs. radiolucent carbon‐fiber‐reinforced PEEK systemsJournal of Applied Clinical Medical Physics, 2020
- Tolerance limits and methodologies forIMRTmeasurement‐based verificationQA:Recommendations ofAAPMTask Group No. 218Medical Physics, 2018
- Dosimetric characterization of carbon fiber stabilization devices for post-operative particle therapyPhysica Medica, 2017
- The impact of smart metal artefact reduction algorithm for use in radiotherapy treatment planningAustralasian Physics & Engineering Sciences in Medicine, 2017
- Perturbation effects of the carbon fiber‐PEEK screws on radiotherapy dose distributionJournal of Applied Clinical Medical Physics, 2017
- International Spine Radiosurgery Consortium Consensus Guidelines for Target Volume Definition in Spinal Stereotactic RadiosurgeryInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012