Do Esophageal pH Monitoring Data Depend on Recording Equipment and Probes?
Authors:
- Harry GoyvaertsHGHarry Goyvaerts
- Rudy HelvenRHRudy Helven
- 1 April 1990
- journal article
- research article
- Published by Wiley in Journal of Pediatric Gastroenterology and Nutrition
- Vol. 10 (3) , 322-326
Abstract
Esophageal pH monitoring data are influenced by numerous patient- and/or technical equipment-related factors. In this study, data obtained with 10 pH recording devices of two different companies and 10 pH glass-microelectrodes with an external reference electrode of one company, calibrated by different persons, were compared. Pearson correlation coefficients regarding the reflux index (the percentage of the investigation time with a pH < 4) ranged from 0.93 to 1.00. The lowest correlation coefficient (0.73) was obtained by comparing the number of episodes with a pH < 4 recorded with devices from different companies. These results suggest that differences in pH monitoring data recorded in comparable conditions with one type of pH electrode are irrevelant as far as clinical routine investigations are concerned. Data are not significantly influenced by the recording devices themselves, the age of the electrodes, or the skin-potential differences induced by the person calibrating the probes.Keywords
This publication has 12 references indexed in Scilit:
- Incidence of Gastroesophageal Reflux in Sleep, Awake, Fasted, and Postcibal Periods in Asymptomatic and Symptomatic InfantsJournal of Pediatric Gastroenterology and Nutrition, 1988
- Simultaneous pH Recordings from Multiple Esophageal Sites in Children with and without Distal Gastroesophageal RefluxJournal of Pediatric Gastroenterology and Nutrition, 1988
- Continuous 24-Hour Esophageal pH Monitoring in 285 Asymptomatic Infants 0–15 Months OldJournal of Pediatric Gastroenterology and Nutrition, 1987
- Influence of Xanthines on Gastroesophageal Reflux in Infants at Risk for Sudden Infant Death SyndromePediatrics, 1986
- Seventeen-Hour Continuous Esophageal pH Monitoring in the NewbornJournal of Pediatric Gastroenterology and Nutrition, 1985
- Apnea associated with regurgitation in infantsThe Journal of Pediatrics, 1985
- Positioning for prevention of infant gastroesophageal refluxThe Journal of Pediatrics, 1983
- Continuous monitoring of distal esophageal pH: A diagnostic test for gastroesophageal reflux in infantsThe Journal of Pediatrics, 1980
- Gastroesophageal reflux causing respiratory distress and apnea in newborn infantsThe Journal of Pediatrics, 1979
- The Role of Intraluminal Junction Potentials in the Generation of the Gastric Potential Difference in ManGastroenterology, 1979