A triple-axis hybrid-linearity selective gradient field system design in magnetic hyperthermia: Providing a spheroidal shaped field-free region
Open Access
- 23 February 2026
- journal article
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (8)
Abstract
Magnetic nanoparticles (MNPs) have emerged as transformative agents in precision oncology due to their tumor-targeting specificity, non-invasive nature, and biocompatibility, particularly in magnetic hyperthermia (MH). Conventional targeted MH systems rely on single-axis gradient selective fields to generate irregular field-free regions (FFRs). This leads to anisotropic heating and compromised targeting accuracy. To address these limitations, this study introduces a triple-axis hybrid-linearity gradient field system that applies a single-axis nonlinear adjustment field to a double-axis linear basement field. This configuration achieves approximate-isotropic gradient distribution, producing spheroidal FFRs with enhanced spatial symmetry. Finite-element simulations demonstrate an obvious reduction in heating zone volume compared to conventional single- or dual-axis systems, significantly reducing off-target heating effects. Experiment using Fe3O4 nanoparticles confirms selective MH efficacy, with FFR temperatures rising by 15.4 °C while unselected regions remain unheated (temperature rise less than 2 °C). An adaptive pre-mapping protocol further optimizes targeting precision, reducing FFR positioning errors to below 20% within a 50 mm workspace. This resolves anisotropic expansion issues inherent to purely linear systems. Despite requiring higher energy input (25 A DC current) than traditional setups, the system enables spatially confined energy deposition with reduced collateral tissue damage. These advancements highlight its clinical potential for tumor-specific therapy and controlled drug delivery. Future efforts should focus on enhancing power efficiency through coil geometry optimization. Integrating real-time field monitoring could also facilitate the real-time selective heating accuracy and operational stability. By proposing a possible system design, this work establishes a novel hybrid-linear modeling and design method for a precise magnetic hyperthermia system.Keywords
Funding Information
- Beijing Municipal Fund for Distinguished Young Scholars (JQ22022)
- The National Key R&D Program of China (Grant No.2022YFF1502000)
This publication has 48 references indexed in Scilit:
- Physicochemical Necessary and Sufficient Conditions for Superferromagnetism in High‐Resolution Magnetic Particle ImagingSmall, 2025
- Biomimetic Robotics and Intelligence: A SurveySmartBot, 2025
- Robotic‐Assisted Endovascular Embolization: Progress and Future PerspectivesSmartBot, 2025
- Bio‐Integrated Microrobots: Fabrication, Actuation and Biomedical ApplicationsSmartBot, 2025
- Ranking Magnetic Colloid Performance for Magnetic Particle Imaging and Magnetic Particle HyperthermiaAdvanced Functional Materials, 2024
- Biocompatible Ferrofluid‐Based Millirobot for Tumor Photothermal Therapy in Near‐Infrared‐II WindowAdvanced Healthcare Materials, 2023
- Precise Control of Customized Macrophage Cell Robot for Targeted Therapy of Solid Tumors with Minimal InvasionSmall, 2021
- Reconfigurable Swarms of Ferromagnetic Colloids for Enhanced Local HyperthermiaAdvanced Functional Materials, 2018
- New head gradient coil design and construction techniquesJournal of Magnetic Resonance Imaging, 2013
- Theory of gradient coil design methods for magnetic resonance imagingConcepts in Magnetic Resonance Part A, 2010