Heating, Ventilation, and Air Conditioning System Optimization Control Strategy Involving Fan Coil Unit Temperature Control
Open Access
- 11 June 2019
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 9 (11) , 2391
Abstract
The objective of this study was to develop a heating, ventilation, and air conditioning (HVAC) system optimization control strategy involving fan coil unit (FCU) temperature control for energy conservation in chilled water systems to enhance the operating efficiency of HVAC systems. The proposed control strategy involves three techniques, which are described as follows. The first technique is an algorithm for dynamic FCU temperature setting, which enables the FCU temperature to be set in accordance with changes in the outdoor temperature to satisfy the indoor thermal comfort for occupants. The second technique is an approach for determining the indoor cold air demand, which collects the set FCU temperature and converts it to the refrigeration ton required for the chilled water system; this serves as the control target for ensuring optimal HVAC operation. The third technique is a genetic algorithm for calculating the minimum energy consumption for an HVAC system. The genetic algorithm determines the pump operating frequency associated with minimum energy consumption per refrigeration ton to control energy conservation. To demonstrate the effectiveness of the proposed HVAC system optimization control strategy combining FCU temperature control, this study conducted a field experiment. The results revealed that the proposed strategy enabled an HVAC system to achieve 39.71% energy conservation compared with an HVAC system operating at full load.Keywords
Funding Information
- Bureau of Energy, Ministry of Economic Affairs, Republic of Taiwan (108-E0203)
This publication has 20 references indexed in Scilit:
- Evaluation on classroom thermal comfort and energy performance of passive school building by optimizing HVAC control systemsBuilding and Environment, 2015
- Thermal comfort control using a non-linear MPC strategy: A real case of study in a bioclimatic buildingJournal of Process Control, 2014
- User-led decentralized thermal comfort driven HVAC operations for improved efficiency in office buildingsEnergy and Buildings, 2014
- Dynamic Demand Response Controller Based on Real-Time Retail Price for Residential BuildingsIEEE Transactions on Smart Grid, 2014
- Optimization of water-cooled chiller system with load-based speed controlApplied Energy, 2008
- A review on buildings energy consumption informationEnergy and Buildings, 2008
- Transient simulation of vapour-compression packaged liquid chillersInternational Journal of Refrigeration, 2002
- Extension of the PMV model to non-air-conditioned buildings in warm climatesEnergy and Buildings, 2002
- Global optimization of absorption chiller system by genetic algorithm and neural networkEnergy and Buildings, 2002
- HVAC control strategies to enhance comfort and minimise energy usageEnergy and Buildings, 2001