Glucose-sensitive nanofiber scaffolds with an improved sensing design for physiological conditions
Open Access
- 26 November 2014
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 140 (3) , 716-723
Abstract
Continuous physiological monitoring of electrolytes and small molecules such as glucose, creatinine, and urea is currently unavailable but achieving such a capability would be a major milestone for personalized medicine. Optode-based nanosensors are an appealing analytical platform for designing in vivo monitoring systems. In addition to the necessary analytical performance, such nanosensors must also be biocompatible and remain immobile at the implantation site. Blood glucose in particular remains a difficult but high-value analyte to monitor continuously. Previously, we developed glucose-sensitive nanosensors that measure glucose by a competitive binding mechanism between glucose and a fluorescent dye to 4-carboxy-3-fluorophenyl boronic acid. To improve the sensitivity and residency time of our reported sensors, we present here a series of new derivatives of 4-carboxy-3-fluorophenyl boronic acid that we screened in a macrosensor format before translating into a nanofiber format with electrospinning. The lead candidate was then implanted subdermally and its residency time was compared to spherical nanosensor analogues. The nanofiber scaffolds were markedly more stable at the implantation site whereas spherical nanosensors diffused away within three hours. Based on the enhanced sensitivity of the new boronic acids and the residency time of nanofibers, this sensor configuration is an important step towards continuous monitoring of glucose and other analytes.Keywords
Funding Information
- National Institutes of Health (5RO1GM084366)
This publication has 35 references indexed in Scilit:
- Long-term in vivo glucose monitoring using fluorescent hydrogel fibersProceedings of the National Academy of Sciences, 2011
- A facile and sensitive fluorescent sensor using electrospun nanofibrous film for nitroaromatic explosive detectionJournal of Materials Chemistry, 2011
- Emission based sub-nanomolar silver sensing with electrospun nanofibersSensors and Actuators B: Chemical, 2011
- Microworm optode sensors limit particle diffusion to enable in vivo measurementsProceedings of the National Academy of Sciences, 2011
- In vivosodium concentration continuously monitored with fluorescent sensorsIntegrative Biology, 2010
- Fluorescent Nano-Optodes for Glucose DetectionAnalytical Chemistry, 2010
- Photonic Crystal Glucose-Sensing Material for Noninvasive Monitoring of Glucose in Tear FluidClinical Chemistry, 2004
- A Microscopic, Continous, Optical Monitor for Interstitial Electrolytes and GlucoseChemphyschem, 2003
- Legume lectin structureBiochimica et Biophysica Acta (BBA) - Protein Structure and Molecular Enzymology, 1998
- Simple Method for the Esterification of Carboxylic AcidsAngewandte Chemie International Edition, 1978