Dynamic behaviour of pre-stressed concrete transmission poles under synoptic wind loading
- 17 January 2022
- journal article
- research article
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 25 (4) , 685-697
Abstract
A numerical model capable of predicting the dynamic response of pre-stressed concrete transmission poles under both the mean and fluctuating components of synoptic wind loads is developed in this study. A full non-linear dynamic analysis is conducted under a time history variation of wind velocity. The peak total responses, such as conductors’ reactions and poles’ base moments, are determined from this analysis. The same analysis is repeated in a quasi-static manner. Dynamic amplification factors (DAF), defined as the ratio between the maximum response based on a non-linear dynamic analysis and the corresponding value based on a quasi-static analysis, are calculated for the poles and the conductors to quantify the dynamic impact of synoptic wind loads. This factor is used to assess the importance of including the resonant component while estimating the response of the transmission poles. In addition, gust response factors (GRF) defined as the ratio between the peak and mean responses are evaluated and compared to GRF recommended by ASCE-74 (2010). A parametric study is conducted on three pre-stressed concrete transmission line systems. The mean value of the incoming wind speed is the main variable included in the parametric study. It is found that the resonant effect is dominant in the conductors at low wind speeds and the poles exhibit high dynamic response at higher wind speeds.Keywords
Funding Information
- Centre for Energy Advancement through Technological Innovation
This publication has 22 references indexed in Scilit:
- High-voltage transmission tower-line system subjected to disaster loadsProgress in Natural Science: Materials International, 2006
- Numerical and analytical simulation of downburst wind loadsEngineering Structures, 2006
- Nonlinear spectral dynamic analysis of guyed towers. Part II: Manitoba towers case studyCanadian Journal of Civil Engineering, 2004
- Parametric study on the along-wind response of the CAARC building to downbursts in the time domainJournal of Wind Engineering and Industrial Aerodynamics, 2004
- A deterministic–stochastic hybrid model of downbursts and its impact on a cantilevered structureEngineering Structures, 2004
- The influence of the design methodology in the response of transmission towers to wind loadingJournal of Wind Engineering and Industrial Aerodynamics, 2003
- A stochastic model of severe thunderstorms for transmission line designProbabilistic Engineering Mechanics, 2000
- Finite elements method for the dynamic analysis of tapered composite polesComposite Structures, 1998
- The effects of high winds on transmission linesJournal of Wind Engineering and Industrial Aerodynamics, 1998
- Full-scale measurements of wind-induced vibration of a transmission line system in a mountainous areaJournal of Wind Engineering and Industrial Aerodynamics, 1997