Enhancing Sensitivity in Headspace-Mass Spectrometric Determination of BTEX in Drinking Water
Authors:
- 6 March 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (7) , 2997-3002
Abstract
A way to extract useful chemical information from the volatile profile provided by a headspace-mass spectrometer (HS-MS) is developed in order to improve sensitivity in HS-MS analysis. The methodology is based on the selection of a narrow window in the volatile profile where the signal-to-noise ratio was maximal by combining the data acquisition time and scan rate. To test this approach, benzene, toluene, ethylbenzene, and p-xylene (BTEX) as well as their mixtures were quantified in drinking waters. Individual hydrocarbons were determined between 1 and 30 μg/L (mean RSD, 4.0% for 10 μg/L) while mixtures were quantified at a microgram per liter level by using the partial least-squares multivariate algorithm with a relative standard prediction error of under 3.5%. These results indicate that the method proposed is useful as a sensitive and selective tool for the determination of BTEX and surpasses other reported HS-MS alternatives. In addition, the proposed methodology can be extended to others that insert analytes from a sample directly into a MS, such as membrane introduction mass spectrometry among others.Keywords
This publication has 12 references indexed in Scilit:
- Detection and quantification of chemical plumes using a portable underwater membrane introduction mass spectrometerTrAC Trends in Analytical Chemistry, 2006
- Direct olive oil authentication: Detection of adulteration of olive oil with hazelnut oil by direct coupling of headspace and mass spectrometry, and multivariate regression techniquesJournal of Chromatography A, 2005
- Factors affecting signal intensity in headspace mass spectrometry for the determination of hydrocarbon pollution in beach sandsAnalytical and Bioanalytical Chemistry, 2005
- Determination of ageing time of spirits in oak barrels using a headspace–mass spectrometry (HS-MS) electronic nose system and multivariate calibrationAnalytical and Bioanalytical Chemistry, 2005
- Electronic noses in the quality control of alcoholic beveragesTrAC Trends in Analytical Chemistry, 2005
- Direct screening of olive oil samples for residual benzene hydrocarbon compounds by headspace-mass spectrometryAnalytica Chimica Acta, 2004
- Fast screening method for determining 2,4,6-trichloroanisole in wines using a headspace?mass spectrometry (HS?MS) system and multivariate calibrationAnalytical and Bioanalytical Chemistry, 2003
- Direct sampling of orujo oil for determining residual hexane by using a chemsensorJournal of the American Oil Chemists' Society, 2003
- Detection of adulterants in olive oil by headspace–mass spectrometryJournal of Chromatography A, 2002
- Selection of optimal regression models via cross‐validationJournal of Chemometrics, 1988