Abstract
The passive magnetic ferrite components used in EMI filters have a complex magnetic permeability (CMP) which varies with frequency. The CMP in frequency range from 150 kHz to 30MHz is not given by manufactures. Moreover, measurement techniques require some specific size and shape of sample to measure CMP of ferrites. Common application of these passives components are EMI filters, where toroid ferrite cores need to be characterized to determine the insertion loss function. In this paper a CMP measure procedure is proposed. The leakage inductance and parasitic capacitance of an inductor are determined. Then, a rational function approximation (RTA) is applied to represent the HF equivalent impedance of CMP.Keywords
This publication has 7 references indexed in Scilit:
- Automatic identification of magnetic component equivalent circuits using impedance measurements2011
- Determination of the stray capacitance of single layer solenoids2011
- Improving reliability of magnetic mutual impedance measurement at high excitation level2011
- EMI filter design for high switching frequency three-phase/level PWM rectifier systems2010
- High-performance permeability measurements: A case study at CERN2010
- Snoek’s limit in high-frequency permeability of polycrystalline Ni–Zn, Mg–Zn, and Ni–Zn–Cu spinel ferritesJournal of Applied Physics, 2000