Evaluation of RealStar Reverse Transcription–Polymerase Chain Reaction Kits for Filovirus Detection in the Laboratory and Field
Open Access
- 21 August 2016
- journal article
- research article
- Published by Oxford University Press (OUP) in The Journal of Infectious Diseases
- Vol. 214 (suppl 3) , S243-S249
Abstract
Background. Diagnosis of Ebola virus (EBOV) disease (EVD) requires laboratory testing. Methods. The RealStar Filovirus Screen reverse transcription–polymerase chain reaction (RT-PCR) kit and the derived RealStar Zaire Ebolavirus RT-PCR kit were validated using in vitro transcripts, supernatant of infected cell cultures, and clinical specimens from patients with EVD. Results. The Filovirus Screen kit detected EBOV, Sudan virus, Taï Forest virus, Bundibugyo virus, Reston virus, and Marburg virus and differentiated between the genera Ebolavirus and Marburgvirus. The amount of filovirus RNA that could be detected with a probability of 95% ranged from 11 to 67 RNA copies/reaction on a LightCycler 480 II. The Zaire Ebolavirus kit is based on the Filovirus Screen kit but was optimized for detection of EBOV. It has an improved signal-to-noise ratio at low EBOV RNA concentrations and is somewhat more sensitive than the Filovirus kit. Both kits show significantly lower analytical sensitivity on a SmartCycler II. Clinical evaluation revealed that the SmartCycler II, compared with other real-time PCR platforms, decreases the clinical sensitivity of the Filovirus Screen kit to diagnose EVD at an early stage. Conclusions. The Filovirus Screen kit detects all human-pathogenic filoviruses with good analytical sensitivity if performed on an appropriate real-time PCR platform. High analytical sensitivity is important for early diagnosis of EVD.Keywords
Funding Information
- European Union's Horizon 2020 (666100)
- Directorate-General for International Cooperation and Development (IFS/2011/272-372)
- European Fund for Regional Development (BWF/H/52228/2012/13.10.10-1/3.4,6)
This publication has 17 references indexed in Scilit:
- Acute respiratory distress syndrome after convalescent plasma use: treatment of a patient with Ebola virus disease contracted in Madrid, SpainThe Lancet Respiratory Medicine, 2015
- Difficulties of interpretation of Zaire Ebola Virus PCR results and implication in the fieldJournal of Clinical Virology, 2015
- A Case of Severe Ebola Virus Infection Complicated by Gram-Negative SepticemiaNew England Journal of Medicine, 2014
- Detection of all known filovirus species by reverse transcription-polymerase chain reaction using a primer set specific for the viral nucleoprotein geneJournal of Virological Methods, 2011
- Comprehensive Panel of Real-Time TaqMan™ Polymerase Chain Reaction Assays for Detection and Absolute Quantification of Filoviruses, Arenaviruses, and New World HantavirusesThe American Journal of Tropical Medicine and Hygiene, 2010
- Diagnostic Reverse‐Transcription Polymerase Chain Reaction Kit for Filoviruses Based on the Strain Collections of all European Biosafety Level 4 LaboratoriesThe Journal of Infectious Diseases, 2007
- The ecology of Ebola virusTrends in Microbiology, 2007
- Rapid Diagnosis of Ebola Hemorrhagic Fever by Reverse Transcription-PCR in an Outbreak Setting and Assessment of Patient Viral Load as a Predictor of OutcomeJournal of Virology, 2004
- Development and Evaluation of a Fluorogenic 5′ Nuclease Assay To Detect and Differentiate between Ebola Virus Subtypes Zaire and SudanJournal of Clinical Microbiology, 2001
- Development and evaluation of a fluorogenic 5′-nuclease assay to identify Marburg virusMolecular and Cellular Probes, 2001