In Vivo T1 of Blood Measurements in Children with Sickle Cell Disease Improve Cerebral Blood Flow Quantification from Arterial Spin-Labeling MRI
Authors:
- L. VáclavůLVL. Václavů
- V. van der LandVLV. van der Land
- D.F.R. HeijtelDHD.F.R. Heijtel
- M.J.P. van OschMOM.J.P. van Osch
- M.H. CnossenMCM.H. Cnossen
- C.B.L.M. MajoieCMC.B.L.M. Majoie
- A. BushABA. Bush
- J.C. WoodJWJ.C. Wood
- K.J. FijnvandraatKFK.J. Fijnvandraat
- H.J.M.M. MutsaertsHMH.J.M.M. Mutsaerts
- A.J. NederveenANA.J. Nederveen
Open Access
- 26 May 2016
- journal article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (9) , 1727-1732
Abstract
BACKGROUND AND PURPOSE: Children with sickle cell disease have low hematocrit and elevated CBF, the latter of which can be assessed with arterial spin-labeling MR imaging. Quantitative CBF values are obtained by using an estimation of the longitudinal relaxation time of blood (T1blood). Because T1blood depends on hematocrit in healthy individuals, we investigated the importance of measuring T1blood in vivo with MR imaging versus calculating it from hematocrit or assuming an adult fixed value recommended by the literature, hypothesizing that measured T1blood would be the most suited for CBF quantification in children with sickle cell disease. MATERIALS AND METHODS: Four approaches for T1blood estimation were investigated in 39 patients with sickle cell disease and subsequently used in the CBF quantification from arterial spin-labeling MR imaging. First, we used 1650 ms as recommended by the literature (T1blood-fixed); second, T1blood calculated from hematocrit measured in patients (T1blood-hematocrit); third, T1blood measured in vivo with a Look-Locker MR imaging sequence (T1blood-measured); and finally, a mean value from T1blood measured in this study in children with sickle cell disease (T1blood–sickle cell disease). Quantitative flow measurements acquired with phase-contrast MR imaging served as reference values for CBF. RESULTS: T1blood-measured (1818 ± 107 ms) was higher than the literature recommended value of 1650 ms, was significantly lower than T1blood-hematocrit (2058 ± 123 ms, P < .001), and, most interesting, did not correlate with hematocrit measurements. Use of either T1blood-measured or T1blood–sickle cell disease provided the best agreement on CBF between arterial-spin labeling and phase-contrast MR imaging reference values. CONCLUSIONS: This work advocates the use of patient-specific measured T1blood or a standardized value (1818 ms) in the quantification of CBF from arterial spin-labeling in children with SCD.Keywords
This publication has 39 references indexed in Scilit:
- Longitudinal Reproducibility and Accuracy of Pseudo-Continuous Arterial Spin–labeled Perfusion MR Imaging in Typically Developing ChildrenRadiology, 2012
- Sickle Cell Disease: Reference Values and Interhemispheric Differences of Nonimaging Transcranial Doppler Blood Flow ParametersAmerican Journal of Neuroradiology, 2011
- A method for rapid in vivo measurement of blood T1NMR in Biomedicine, 2011
- In vivo venous blood T1 measurement using inversion recovery true‐FISP in children and adultsMagnetic Resonance in Medicine, 2010
- Quantification Issues in Arterial Spin Labeling Perfusion Magnetic Resonance ImagingTopics in Magnetic Resonance Imaging, 2010
- Estimation of labeling efficiency in pseudocontinuous arterial spin labelingMagnetic Resonance in Medicine, 2010
- Red blood cell aggregation, aggregate strength and oxygen transport potential of blood are abnormal in both homozygous sickle cell anemia and sickle-hemoglobin C diseaseHaematologica, 2009
- Hemodynamic Etiology of Elevated Flow Velocity and Stroke in Sickle-Cell DiseaseJournal of Cerebral Blood Flow & Metabolism, 2009
- Inverse correlation between cerebral blood flow measured by continuous arterial spin-labeling (CASL) MRI and neurocognitive function in children with sickle cell anemia (SCA)Blood, 2006
- Abnormal Adherence of Sickle Erythrocytes to Cultured Vascular EndotheliumJournal of Clinical Investigation, 1980