A film-lever actuated switch technology for multifunctional, on-demand, and robust manipulation of liquids
Open Access
- 20 August 2022
- journal article
- research article
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-13
Abstract
A lab-on-a-chip system with Point-of-Care testing capability offers rapid and accurate diagnostic potential and is useful in resource-limited settings where biomedical equipment and skilled professionals are not readily available. However, a Point-of-Care testing system that simultaneously possesses all required features of multifunctional dispensing, on-demand release, robust operations, and capability for long-term reagent storage is still a major challenge. Here, we describe a film-lever actuated switch technology that can manipulate liquids in any direction, provide accurate and proportional release response to the applied pneumatic pressure, as well as sustain robustness during abrupt movements and vibrations. Based on the technology, we also describe development of a polymerase chain reaction system that integrates reagent introduction, mixing and reaction functions all in one process, which accomplishes “sample-in-answer-out” performance for all clinical nasal samples from 18 patients with Influenza and 18 individual controls, in good concordance of fluorescence intensity with standard polymerase chain reaction (Pearson coefficients > 0.9). The proposed platform promises robust automation of biomedical analysis, and thus can accelerate the commercialization of a range of Point-of-Care testing devices.Keywords
This publication has 58 references indexed in Scilit:
- An integrated chip capable of performing sample pretreatment and nucleic acid amplification for HIV-1 detectionBiosensors and Bioelectronics, 2013
- Fully Enclosed Microfluidic Paper-Based Analytical DevicesAnalytical Chemistry, 2012
- A pneumatic micropump incorporated with a normally closed valve capable of generating a high pumping rate and a high back pressureMicrofluidics and Nanofluidics, 2008
- Silane–dextran chemistry on lateral flow polymer chips for immunoassaysLab on a Chip, 2008
- Optimization of poly-di-methyl-siloxane (PDMS) substrates for studying cellular adhesion and motilityMicroelectronic Engineering, 2008
- A membrane-based serpentine-shape pneumatic micropump with pumping performance modulated by fluidic resistanceJournal of Micromechanics and Microengineering, 2008
- Batch-mode mixing on centrifugal microfluidic platformsLab on a Chip, 2005
- Chaotic Mixer for MicrochannelsScience, 2002
- Studies on polymer latex films: IV. Comparison of the permeability of latex and solvent‐cast filmsPolymer International, 1992
- Water permeation through elastomer laminates: 3. Neoprene/styrene-butadiene rubberPolymer, 1986