Knudsen pump produced via silicon deep RIE, thermal oxidation, and anodic bonding processes for on-chip vacuum pumping
- 23 February 2018
- journal article
- research article
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 28 (5) , 055001
Abstract
This work describes the fabrication and evaluation of the Knudsen pump for on-chip vacuum pumping that works based on the principle of a thermal transpiration. Three AFM (atomic force microscope) cantilevers are integrated into small chambers with a size of 5 mm × 3 mm × 0.4 mm for the pump’s evaluation. Knudsen pump is fabricated using deep RIE (reactive ion etching), wet thermal oxidation and anodic bonding processes. The fabricated device is evaluated by monitoring the quality ( Q ) factor of the integrated cantilevers. The Q factor of the cantilever is increased from 300 –1150 in cases without and with a temperature difference approximately 25 °C between the top (the hot side at 40 °C) and bottom (the cold side at 15 °C) sides of the fabricated device, respectively. The evacuated chamber pressure of around 10 kPa is estimated from the Q factor of the integrated cantilevers.Keywords
This publication has 24 references indexed in Scilit:
- A Long Bar Type Silicon Resonator with a High Quality FactorIEEJ Transactions on Sensors and Micromachines, 2014
- Fabrication of an hermetically packaged silicon resonator on LTCC substrateMicrosystem Technologies, 2012
- A Si-micromachined 48-stage Knudsen pump for on-chip vacuumJournal of Micromechanics and Microengineering, 2012
- Tube-shaped Pirani gauge forin situhermeticity monitoring of SiN thin-film encapsulationJournal of Micromechanics and Microengineering, 2012
- Metal-organic thin-film encapsulation for MEMSJournal of Micromechanics and Microengineering, 2008
- Wafer level packaging of MEMSJournal of Micromechanics and Microengineering, 2008
- Fabrication of high-density electrical feed-throughs by deep-reactive-ion etching of Pyrex glassJournal of Microelectromechanical Systems, 2002
- A vacuum packaged surface micromachined resonant accelerometerJournal of Microelectromechanical Systems, 2002
- A valveless diffuser/nozzle-based fluid pumpSensors and Actuators A: Physical, 1993
- Eine Revision der Gleichgewichtsbedingung der Gase. Thermische MolekularströmungAnnalen der Physik, 1909