Accelerating GenSeT Reconstruction for Sparsely Sampled DCE-MRI with GPU
- 1 December 2018
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 29-34
Abstract
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) uses radioactive contrast agents as a tracer to provide tumor morphology and contrast kinetics information of tumor regions, which are crucial in breast cancer diagnosis and treatment. The effectiveness of the imaging modality relies on its capacity to acquire dynamic data at a sufficient sampling rate to gain the desired temporal resolution. This can be achieved by sparsely sampling the k-space data and applying advanced image reconstruction method that exploits compressed sensing, such as the recently proposed GenSeT (Generalized Series with Temporal constraint) method. Due to the highly nonlinear nature of compressed-sensing-based approach, computational complexity of the reconstruction algorithm is a practical challenge, especially for large breast DCE-MRI datasets. In this study, the GenSeT algorithm was implemented in GPU using CUDA platform to significantly reduce reconstruction time, yielding a much more practical solution. Experimental results showed that for a breast DCE-MRI data, the proposed GPU-based GenSeT implementation achieved approximately 48 times faster in the reconstruction time as compared to the CPU approach, without sacrificing the image quality. Although this work focuses on accelerating image reconstruction for sparsely-sampled breast DCE-MRI, the proposed GPU-based algorithm can be easily applied for sparsely sampled DCE-MRI of other organs.Keywords
This publication has 16 references indexed in Scilit:
- Research on the conjugate gradient algorithm with a modified incomplete Cholesky preconditioner on GPUJournal of Parallel and Distributed Computing, 2014
- Variable-density spiral-in/out functional magnetic resonance imagingMagnetic Resonance in Medicine, 2010
- Dynamic MRA With Four-Dimensional Time-Resolved Angiography Using Keyhole at 3 Tesla in Head and Neck Vascular LesionsJournal of Neuro-Ophthalmology, 2009
- Optimal k‐space sampling for dynamic contrast‐enhanced MRI with an application to MR renographyMagnetic Resonance in Medicine, 2009
- Three‐dimensional dynamic time‐resolved contrast‐enhanced MRA using parallel imaging and a variable rate k‐space sampling strategy in intracranial arteriovenous malformationsJournal of Magnetic Resonance Imaging, 2008
- 4D time‐resolved MR angiography with keyhole (4D‐TRAK): More than 60 times accelerated MRA using a combination of CENTRA, keyhole, and SENSE at 3.0TJournal of Magnetic Resonance Imaging, 2008
- Smooth minimization of non-smooth functionsMathematical Programming, 2004
- Temporal sampling requirements for the tracer kinetics modeling of breast diseaseMagnetic Resonance Imaging, 1998
- HASTE MR imaging: Description of technique and preliminary results in the abdomenJournal of Magnetic Resonance Imaging, 1996
- Continuous Update with Random Encoding (CURE): A New Strategy for Dynamic ImagingMagnetic Resonance in Medicine, 1995