SEM analysis of defects and wear on Ni–Ti rotary instruments
Abstract
Summary: SEM analysis of endodontic instruments from a Ni–Ti rotary system was assessed, before and after using them, considering their defects and deformations. Twenty Twisted File®, BioRąCe®, Mtwo®, and EndoWave® instruments were micrographed at 190× magnification. The files were washed and micrographed again to view alterations as to the presence or absence of irregular edges, grooves, microcavities, and scraping. Simulated root canal preparations were performed using these instruments. The instruments were cleaned and received a microscopic analysis after being used five times. After analysis tests were tested using Fisher's exact test and Kappa to evaluate the concordance among examiners. There was a statistically significant difference with respect to deformations between Twisted File® and other instruments (p < 0.05). There was no statistically significant difference in strains between the other groups (p > 0.05). All Twisted File® instruments showed the same defects; however damage were lower than those found in BioRace® and Mtwo®. The Endowave® did not show the same defects. In accordance with the data we conclude that the presence of defects was higher in Twisted File® instruments as the instruments and BioRace® Mtwo® brand, the defect rate was smaller and Endowave® instruments had no defects. Regarding the presence of wear after five uses among the groups all instruments showed changes in their cutting blades. SCANNING 36:411–418, 2014.Keywords
This publication has 20 references indexed in Scilit:
- A comparison of nickel-titanium rotary instruments manufactured using different methods and cross-sectional areas: ability to resist cyclic fatigueOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2010
- Fatigue Resistance of Engine-driven Rotary Nickel-Titanium Instruments Produced by New Manufacturing MethodsJournal of Endodontics, 2008
- Pitting Corrosion Resistance of Nickel–Titanium Rotary Instruments with Different Surface Treatments in Seventeen Percent Ethylenediaminetetraacetic Acid and Sodium Chloride SolutionsJournal of Endodontics, 2008
- Fracture Resistance of Electropolished Rotary Nickel–Titanium Endodontic InstrumentsJournal of Endodontics, 2007
- Deformation and fracture of RaCe and K3 endodontic instruments according to the number of usesInternational Endodontic Journal, 2006
- The effect of pre‐soaking and time in the ultrasonic cleaner on the cleanliness of sterilized endodontic filesInternational Endodontic Journal, 2006
- Comparative investigation of two rotary nickel–titanium instruments: ProTaper versus RaCe. Part 1. Shaping ability in simulated curved canalsInternational Endodontic Journal, 2004
- Comparative investigation of two rotary nickel–titanium instruments: ProTaper versus RaCe. Part 2. Cleaning effectiveness and shaping ability in severely curved root canals of extracted teethInternational Endodontic Journal, 2004
- Wear of nickel-titanium lightspeed instruments evaluated by scanning electron microscopyJournal of Endodontics, 1999
- A comparison of techniques for cleaning endodontic files after usage: A quantitative scanning electron microscopic studyJournal of Endodontics, 1990