Application of portable spectrometer for ultra trace metal analysis after ionic liquid based microextraction
Authors:
- 9 April 2013
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (12) , 2978-2983
Abstract
In this work, a commercially available portable tungsten coil electrothermal atomic absorption spectrometer (W-coil ET-AAS) was applied and investigated. The portable AAS instrument was developed based on a W-coil atomizer and a charge coupled device detector, and has the characteristics of compactness and portability. In this research, ionic liquid based liquid phase microextraction (IL-LPME) was coupled with a portable AAS instrument to expand its application and improve its analytical performance. Ultra trace lead and copper were investigated as the target elements in the established coupling. The factors influencing both IL-LPME and the portable spectrometer were optimized. Under the optimal conditions, the limits of detection for lead and copper were 0.25 μg L−1 and 0.10 μg L−1, with sensitivity enhancement factors of 38 and 26, respectively. The relative standard deviation (RSD) for seven replicate measurements of 20 μg L−1 of lead was 4.9%, and 10 μg L−1 of copper was 3.4%. The recoveries for the spiked samples were in the acceptable range of 92.7–105%.Keywords
This publication has 23 references indexed in Scilit:
- Hollow fiber supported liquid membrane extraction for ultrasensitive determination of trace lead by portable tungsten coil electrothermal atomic absorption spectrometryMicrochemical Journal, 2010
- Determination of cadmium in rice and water by tungsten coil electrothermal vaporization-atomic fluorescence spectrometry and tungsten coil electrothermal atomic absorption spectrometry after cloud point extractionAnalytica Chimica Acta, 2009
- Evaluation of tungsten coil electrothermal vaporization-Ar/H2 flame atomic fluorescence spectrometry for determination of eight traditional hydride-forming elements and cadmium without chemical vapor generationTalanta, 2008
- Direct determination of cadmium in urine by tungsten-coil inductively coupled plasma atomic emission spectrometry using palladium as a permanent modifierTalanta, 2007
- Tungsten devices in analytical atomic spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 2002
- Determination of selenium by tungsten coil atomic absorption spectrometry using iridium as a permanent chemical modifierSpectrochimica Acta Part B: Atomic Spectroscopy, 2001
- Determination of lead in blood by chelation with ammonium pyrrolidine dithio-carbamate followed by tungsten-coil atomic absorption spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1999
- On-line coupling of electrochemical preconcentration in tungsten coil electrothermal atomic absorption spectrometry for determination of lead in natural watersSpectrochimica Acta Part B: Atomic Spectroscopy, 1999
- Determination of Cadmium with a Portable, Battery-Powered Tungsten Coil Atomic Absorption SpectrometerApplied Spectroscopy, 1998
- On-line separation and preconcentration of cadmium, lead and nickel in a fullerene (C 60 ) minicolumn coupled to flow injection tungsten coil atomic absorption spectrometry 1Presented at the Flow Analysis VII Conference held in Piracicaba, Brazil, 23–26 August 1997. 1Analytica Chimica Acta, 1998