Abstract
The purpose of this study was to quantify the set-up errors of patient positioning during IGRT and to correlate set-up errors to patient-specific factors such as weight, height, BMI, and weight loss. Thirty four consecutively treated head-and-neck cancer patients (H&N) and 20 lung cancer patients were investigated. Patients were positioned using customized immobilization devices consisting of vacuum cushions and thermoplastic shells. Treatment was given on an Elekta Synergy accelerator. Cone-beam acquisitions were obtained according to a standardized Action Limit protocol and compared to pre-treatment CT images. The average 3D deviation from three initial cone beam scans was compared to deviations at the 10th and 20th treatment session and correlated by linear regression analysis to height, weight, and BMI, and in H&N to weight loss as expressed by the relative weight change over time. The SD of the translational and rotational random set-up errors during the first three sessions for H&N were 0.9 mm (Left-Right), 1.1mm (Anterior-Posterior), 0.7 mm (Cranio-Caudal) and 0.7 degrees (LR-axis), 0.5 degrees (AP-axis), and 0.7 degrees (CC-axis). The equivalent data for lung cancer patients were 1.1 mm (LR), 1.1mm (AP), 1.5 mm (CC) and 0.5 degrees (LR-axis), 0.6 degrees (AP-axis), and 0.4 degrees (CC-axis). The median BMI for H&N and lung was 25.8 (17.6-39.7) and 23.7 (17.4-38.8), respectively. The median weekly weight change for H&N was -0.3% (-2.0 to 1.1%). With H&N and lung cancer analyzed separately, no statistically significant correlation was observed between set-up errors and height, weight, BMI, or weight change during treatment, irrespectively whether the 3D deviations from the initial three cone beam scans or scans from the 10th or 20th treatment sessions were used. This IGRT study did not support the hypothesis that set-up errors during radiotherapy are correlated to patient height, weight, BMI, or weight loss.Keywords
This publication has 8 references indexed in Scilit:
- Body Weight Loss Associates With Set-up Error in Nasopharyngeal Cancer Patients Undergoing Image Guided RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Cone Beam Computed Tomography Guidance for Setup of Patients Receiving Accelerated Partial Breast IrradiationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Kilo-Voltage Cone-Beam Computed Tomography Setup Measurements for Lung Cancer Patients; First Clinical Results and Comparison With Electronic Portal-Imaging DeviceInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Evaluation of image-guidance protocols in the treatment of head and neck cancersInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Repeat CT imaging and replanning during the course of IMRT for head-and-neck cancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Five compared with six fractions per week of conventional radiotherapy of squamous-cell carcinoma of head and neck: DAHANCA 6&7 randomised controlled trialThe Lancet, 2003
- Spinal cord and peripheral nerve injury: current management and investigationsSeminars in Radiation Oncology, 2003
- The incidence of myelitis after irradiation of the cervical spinal cordInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1990