We developed a force measurement system in a soil-filled mound for measuring ground reaction forces (GRFs) acting on baseball pitchers and examined the reliability and validity of kinetic and kinematic parameters determined from the GRFs. Three soil-filled trays of dimensions that satisfied the official baseball rules were fixed onto 3 force platforms. Eight collegiate pitchers wearing baseball shoes with metal cleats were asked to throw 5 fastballs with maximum effort from the mound toward a catcher. The reliability of each parameter was determined for each subject as the coefficient of variation across the 5 pitches. The validity of the measurements was tested by comparing the outcomes either with the true values or the corresponding values computed from a motion capture system. The coefficients of variation in the repeated measurements of the peak forces ranged from 0.00 to 0.17, and were smaller for the pivot foot than the stride foot. The mean absolute errors in the impulses determined over the entire duration of pitching motion were 5.3 N˙s, 1.9 N˙s, and 8.2 N˙s for the X-, Y-, and Z-directions, respectively. These results suggest that the present method is reliable and valid for determining selected kinetic and kinematic parameters for analyzing pitching performance.Keywords
This publication has 14 references indexed in Scilit:
- Effects of two football stud configurations on biomechanical characteristics of single-leg landing and cutting movements on infilled synthetic turfSports Biomechanics, 2014
- Biomechanical Comparison of the Interval Throwing Program and Baseball PitchingThe American Journal of Sports Medicine, 2014
- Adolescent Baseball Pitching Technique: Lower Extremity Biomechanical AnalysisJournal of Applied Biomechanics, 2012
- Lower-Extremity Ground Reaction Forces in Collegiate Baseball PitchersJournal of Strength & Conditioning Research, 2012
- A portable system for in-situ re-calibration of force platforms: Experimental validationGait & Posture, 2009
- Accuracy of centre of pressure measurement using a piezoelectric force platformClinical Biomechanics, 1999
- Characteristic Ground-Reaction Forces in Baseball PitchingThe American Journal of Sports Medicine, 1998
- Accuracy of determining the point of force application with piezoelectric force platesJournal of Biomechanics, 1990
- Timing of the Lower Limb Drive and Throwing Limb Movement in Baseball PitchingInternational Journal of Sport Biomechanics, 1988
- A method to determine the angular momentum of a human body about three orthogonal axes passing through its center of gravityJournal of Biomechanics, 1978