Development and validation of LC-MS/MS assay for the determination of Butoconazole in human plasma: Evaluation of systemic absorption following topical application in healthy volunteers
Authors:
- Eman G. NoumanENEman G. Nouman
- Medhat A. Al-GhobashyMAMedhat A. Al-Ghobashy
- Hayam M. LotfyHLHayam M. Lotfy
Open Access
- 1 December 2017
- journal article
- Published by Faculty of Pharmacy Cairo University in Bulletin of Faculty of Pharmacy, Cairo University
- Vol. 55 (2) , 303-310
Abstract
Butoconazole is an imidazole antifungal that is more effective than miconazole and clotrimazole for treatment of vaginal candidiasis. A highly sensitive tandem mass spectrometric assay was developed and validated to evaluate systemic absorption of Butoconazole following intravaginal administration. Chromatographic separation was achieved using Waters Xterra C18 column (3 µm, 3.0 Ã 50.0 mm). Liquid-liquid extraction using tert-butyl methyl ether was used for preparation of plasma samples. The mobile phase was solvent A: 0.1% formic acid in water and solvent B: acetonitrile: methanol (30:70, v/v), using gradient elution mode at 0.5 mL/min. Detection at positive electrospray ionization in the MRM mode was then employed. Analysis was carried out within 5.5 min over a linear concentration range of 0.10â30.00 ng/mL. Validation was carried out according to US FDA guidelines for bioanalytical method validation. Matrix effect, recovery efficiency and process efficiency have been investigated for the analyte and internal standard in neat solvent, post-extraction matrix and plasma. The mean percentage recoveries were higher than 80%, the accuracy was 93.51â106.85% and the RSD was below 10% throughout the studied concentration range. Results indicated sufficient stability of the target analyte in plasma at the employed experimental conditions. Results of incurred sample re-analysis and incurred sample stability revealed less than 5% variability. The applicability of the assay for monitoring of the systemic absorption of Butoconazole following intra vaginal application to healthy volunteers was demonstrated. Results confirmed that Butoconazole was detected shortly after intra vaginal administration with Cmax and tmax of 30 ng/mL and 6 h, respectively. Keywords: Butoconazole, LC-MS/MS, Matrix effect, Process efficiency, Recovery efficiencKeywords
This publication has 14 references indexed in Scilit:
- Development of a liquid chromatography-tandem mass spectrometry method for determination of butoconazole nitrate in human plasma and its application to a pharmacokinetic studyCurrent Medical Science, 2014
- Importance of matrix effects in LC–MS/MS bioanalysisBioanalysis, 2013
- Hidden Killers: Human Fungal InfectionsScience Translational Medicine, 2012
- The vagina as a route for drug delivery: a reviewInternational Urogynecology Journal, 2012
- Butoconazole nitrate pharmacokinetics studied by capillary electrophoresisPharmaceutical Chemistry Journal, 2009
- Preparation and Evaluation of Miconazole Nitrate-Loaded Solid Lipid Nanoparticles for Topical DeliveryAAPS PharmSciTech, 2009
- Evaluation of matrix effect and chromatography efficiency: new parameters for validation of method developmentJournal of the American Society for Mass Spectrometry, 2005
- Stable isotopically labeled internal standards in quantitative bioanalysis using liquid chromatography/mass spectrometry: necessity or not?Rapid Communications in Mass Spectrometry, 2005
- Strategies for the Assessment of Matrix Effect in Quantitative Bioanalytical Methods Based on HPLC−MS/MSAnalytical Chemistry, 2003
- Extreme Vertexes Design in Formulation Development: Solubility of Butoconazole Nitrate in a Multicomponent SystemJournal of Pharmaceutical Sciences, 1981