Modulating Nodal Outflows to Guarantee Sufficient Disinfectant Residuals in Water Distribution Networks
- 1 August 2020
- journal article
- research article
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 146 (8) , 04020066
Abstract
This paper proposes the modulation of nodal outflows in water distribution networks (WDNs) to solve the problem of low disinfectant concentrations at critical dead-end nodes, in which low flow velocities and long residence times cause excessive disinfectant decay. The slight increase in nodal outflows at these sites, which can be obtained through the opening of a blowoff at the hydrant site, can help to address this problem with no need to increase disinfectant doses at the source(s) or of install additional disinfectant booster stations. The methodology is based on the combined use of optimization and flow routing/water quality modeling of WDNs. The concentration of disinfectant at the source(s) and the values of nodal emitter coefficients at the critical dead-end nodes are the decisional variables to be optimized. Two objective functions are considered in the optimization: the total volume of water delivered in the network (inclusive of supply, leakage, and additional nodal outflow considered for fixing disinfectant residuals); and the total mass of disinfectant injected into the network. The effectiveness of the methodology was proven on a real WDN, yielding insight into the economic feasibility of the solution.Keywords
This publication has 18 references indexed in Scilit:
- Planning Unidirectional Flushing Operations as a Response to Drinking Water Distribution System ContaminationJournal of Water Resources Planning and Management, 2010
- Real-Time Optimal Valve Operation and Booster Disinfection for Water Quality in Water Distribution SystemsJournal of Water Resources Planning and Management, 2010
- Impact of Booster Chlorination on Chlorine Decay and THM Production: Simulated AnalysisJournal of Environmental Engineering, 2009
- Linear Least-Squares Formulation for Operation of Booster Disinfection SystemsJournal of Water Resources Planning and Management, 2004
- A reactive species model for chlorine decay and THM formation under rechlorination conditionsWater Research, 2003
- Facility Location Model for Booster Disinfection of Water Supply NetworksJournal of Water Resources Planning and Management, 2002
- Factors which control bulk chlorine decay ratesWater Research, 2000
- Optimal Scheduling of Booster Disinfection in Water Distribution SystemsJournal of Water Resources Planning and Management, 1998
- Modeling Chlorine Residuals in Drinking‐Water Distribution SystemsJournal of Environmental Engineering, 1994
- Chlorination, chlorination by-products, and cancer: a meta-analysis.American Journal of Public Health, 1992