Prospective Trial of a Passive Diversion Device to Reduce Blood Culture Contamination
Open Access
- 23 December 2024
- journal article
- research article
- Published by Oxford University Press (OUP) in Open Forum Infectious Diseases
- Vol. 12 (1) , ofae751
Abstract
Background: Blood culture contaminants can lead to inappropriate antibiotic use, prolonged length of stay, and additional hospital costs. Several devices have been developed to reduce the risk of blood culture contamination by diverting a portion of the initial blood sample from the blood culture bottle. We assessed the effectiveness of 1 blood diversion device (BDD) in a prospective trial performed at the 2 separate emergency departments (EDs) of an academic medical center. Methods: A multiphase prospective crossover trial was performed with the BDD in use at 1 ED and standard equipment at the other ED for 10 weeks, and a second 10-week study phase was conducted with the use of the BDD and standard equipment in the EDs reversed. Contaminants were identified both by standard clinical microbiology lab criteria and by independent retrospective review by 3 infectious disease (ID) physicians. The primary analysis was performed based on intention-to-use data using the physician review of positive blood cultures. Results: A total of 5637 blood samples were obtained, with 5625 samples analyzed after 12 blood culture results were deemed inconclusive by the ID physician review. The University ED had a higher blood culture contamination rate of 2.9% compared with the Memorial ED at 1.4%. In an intention-to-use analysis, the overall contamination rates were 2.0% and 2.9% in the BDD and standard equipment periods, respectively (P = .03), and in an actual-use analysis the contamination rates were 1.2% and 3.0% for the BDD and standard equipment, respectively (P < .001). Conclusions: The BDD was associated with significantly lower blood culture contamination rates at the institution's 2 EDs, with a stronger effect noted at the campus caring for higher acuity patients.Keywords
This publication has 33 references indexed in Scilit:
- Getting to zero: Impact of a device to reduce blood culture contamination and false-positive central-line–associated bloodstream infectionsInfection Control & Hospital Epidemiology, 2022
- Asynchronous Testing of 2 Specimen-Diversion Devices to Reduce Blood Culture Contamination: A Single-Site Product Supply Quality Improvement ProjectJournal of Emergency Nursing, 2021
- The impact of overcrowding on the bacterial contamination of blood cultures in the EDThe American Journal of Emergency Medicine, 2012
- Impact of a blood culture collection kit on the quality of blood culture sampling: fear and the law of unintended consequencesJournal of Hospital Infection, 2011
- Clinical Impact of Blood Cultures Contaminated with Coagulase-Negative Staphylococci at an Academic Medical CenterInfection Control & Hospital Epidemiology, 2011
- Clinical and economic impact of contaminated blood cultures within the hospital settingJournal of Hospital Infection, 2011
- Skin antiseptics in venous puncture-site disinfection for prevention of blood culture contamination: systematic review with meta-analysisJournal of Hospital Infection, 2011
- Analysis of strategies to improve cost effectiveness of blood culturesJournal of Hospital Medicine, 2006
- A randomized trial of povidone-iodine compared with iodine tincture for venipuncture site disinfection: effects on rates of blood culture contaminationThe American Journal of Medicine, 1999
- Contaminant Blood Cultures and Resource UtilizationJAMA, 1991