Effects of alveolar dead-space, shunt anddistribution on respiratory dead-space measurements
Authors:
- M.J. TurnerMTM.J. Turner
- A.B. BakerABA.B. Baker
- 1 October 2005
- journal article
- research article
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 95 (4) , 538-548
Abstract
Respiratory dead-space is often increased in lung disease. This study evaluates the effects of increased alveolar dead-space (Vd(alv)), pulmonary shunt, and abnormal ventilation perfusion ratio (/) distributions on dead-space and alveolar partial pressure of carbon dioxide (Pa(co(2))) calculated by various methods, assesses a recently published non-invasive method (Koulouris method) for the measurement of Bohr dead-space, and evaluates an equation for calculating physiological dead-space (Vd(phys)) in the presence of pulmonary shunt. Pulmonary shunt, / distribution and Vd(alv) were varied in a tidally breathing cardiorespiratory model. Respiratory data generated by the model were analysed to calculate dead-spaces by the Fowler, Bohr, Bohr-Enghoff and Koulouris methods. Pa(co(2)) was calculated by the method of Koulouris. When Vd(alv) is increased, Vd(phys) can be recovered by the Bohr and Bohr-Enghoff equations, but not by the Koulouris method. Shunt increases the calculated Bohr-Enghoff dead-space, but does not affect Fowler, Bohr or Koulouris dead-spaces, or Vd(phys) estimated by the shunt-corrected equation if pulmonary artery catheterization is available. Bohr-Enghoff but not Koulouris or Fowler dead-space increases with increasing severity of / maldistribution. When alveolar Pco(2) is increased by any mechanism, Pa(co(2)) calculated by Koulouris' method does not agree well with average alveolar Pco(2). Our studies show that increased pulmonary shunt causes an apparent increase in Vd(phys), and that abnormal / distributions affect the calculated Vd(phys) and Vd(alv), but not Fowler dead-space. Dead-space and Pa(co(2)) calculated by the Koulouris method do not represent true Bohr dead-space and Pa(co(2)) respectively, but the shunt-corrected equation performs well.Keywords
This publication has 30 references indexed in Scilit:
- Volumetric Capnography as a Screening Test for Pulmonary Embolism in the Emergency DepartmentChest, 2004
- Pulmonary Dead-Space Fraction as a Risk Factor for Death in the Acute Respiratory Distress SyndromeNew England Journal of Medicine, 2002
- Noninvasive measurement of mean alveolar carbon dioxide tension and Bohr's dead space during tidal breathingEuropean Respiratory Journal, 2001
- Diagnostic Accuracy of a Bedside D-dimer Assay and Alveolar Dead-Space Measurement for Rapid Exclusion of Pulmonary EmbolismJAMA, 2001
- Deadspace to tidal volume ratio predicts successful extubation in infants and childrenCritical Care Medicine, 2000
- Utility of deadspace and capnometry measurements in determination of surfactant efficacy in surfactant-depleted lungsCritical Care Medicine, 1999
- Dead space and slope indices from the expiratory carbon dioxide tension-volume curveEuropean Respiratory Journal, 1997
- RELATIONSHIP BETWEEN ALVEOLAR DEADSPACE AND ARTERIAL OXYGENATION IN CHILDREN WITH CONGENITAL CARDIAC DISEASE †British Journal of Anaesthesia, 1989
- LUNG FUNCTION STUDIES. II. THE RESPIRATORY DEAD SPACEAmerican Journal of Physiology-Legacy Content, 1948
- Ueber die Lungenathmung1Skandinavisches Archiv Für Physiologie, 1891