Mid-term survivorship of primary total knee arthroplasty with a specific implant
- 1 March 2023
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 105-B (3) , 277-283
Abstract
Aims: The purpose of this study was to assess mid-term survivorship following primary total knee arthroplasty (TKA) with Optetrak Logic components and identify the most common revision indications at a single institution.Methods: We identified a retrospective cohort of 7,941 Optetrak primary TKAs performed from January 2010 to December 2018. We reviewed the intraoperative findings of 369 TKAs that required revision TKA from January 2010 to December 2021 and the details of the revision implants used. Kaplan-Meier analysis was used to determine survivorship. Cox regression analysis was used to examine the impact of patient variables and year of implantation on survival time.Results: The estimated survivorship free of all-cause revision was 98% (95% confidence interval (CI) 97% to 98%), 95% (95% CI 95% to 96%), and 86% (95% CI 83% to 88%) at two, five, and ten years, respectively. In 209/369 revisions there was a consistent constellation of findings with varying severity that included polyethylene wear and associated synovitis, osteolysis, and component loosening. This failure mode, which we refer to as aseptic mechanical failure, was the most common revision indication. The mean time from primary TKA to revision for aseptic mechanical failure was five years (5 months to 11 years).Conclusion: In this series of nearly 8,000 primary TKAs performed with a specific implant, we identified a lower-than-expected mid-term survivorship and a high number of revisions with a unique presentation. This study, along with the recent recall of the implant, confirms the need for frequent monitoring of patients with Optetrak TKAs given the incidence of polyethylene failure, osteolysis, and component loosening.Cite this article: Bone Joint J 2023;105-B(3):277–283.Keywords
This publication has 16 references indexed in Scilit:
- Unusually High Rate of Early Failure of Tibial Component in ATTUNE Total Knee Arthroplasty System at Implant–Cement InterfaceThe Journal of Knee Surgery, 2017
- Periprosthetic Joint Infection Is the Main Cause of Failure for Modern Knee Arthroplasty: An Analysis of 11,134 KneesClinical Orthopaedics and Related Research, 2017
- Why Are Total Knee Arthroplasties Failing Today—Has Anything Changed After 10 Years?The Journal of Arthroplasty, 2014
- Survival analysis of total knee arthroplasty at a minimum 10 years’ follow-up: A multicenter French nationwide study including 846 casesOrthopaedics & Traumatology: Surgery & Research, 2013
- Aseptic Tibial Debonding as a Cause of Early Failure in a Modern Total Knee Arthroplasty DesignClinical Orthopaedics and Related Research, 2013
- Fifteen-Year to 19-Year Follow-Up of the Insall-Burstein-1 Total Knee ArthroplastyThe Journal of Arthroplasty, 2010
- Wear Rate of Highly Cross-Linked Polyethylene in Total Hip ArthroplastyJournal of Bone and Joint Surgery, 2009
- PFC Knee ReplacementClinical Orthopaedics and Related Research, 2007
- The Coventry Award Paper: Factors Influencing Wear and Osteolysis in Press-Fit Condylar Modular Total Knee ReplacementsClinical Orthopaedics and Related Research, 2004
- Why Are Total Knee Arthroplasties Failing Today?Clinical Orthopaedics and Related Research, 2002