Comparison of invasive and noninvasive blood pressure measurements in critically ill patients receiving norepinephrine
Open Access
- 16 December 2025
- journal article
- research article
- Published by Springer Nature in BMC Anesthesiology
- Vol. 25 (1) , 609
Abstract
Background: Blood pressure monitoring is crucial in critically ill patients, with invasive arterial blood pressure (IABP) recognized as the gold standard. Noninvasive blood pressure (NIBP) is widely used but may differ from IABP, particularly in patients receiving norepinephrine. This study evaluated the agreement between IABP and NIBP and the impact of the norepinephrine dosage on the accuracy of NIBP in septic shock patients. Methods: This prospective observational study was conducted in a 36-bed ICU (April 2022–April 2023) and included 84 patients with septic shock receiving norepinephrine. IABP was measured via a radial artery catheter, and NIBP was recorded simultaneously from the contralateral arm. Patients were grouped by norepinephrine dose: ≤ 0.25, 0.25–0.50, and ≥ 0.50 mcg/kg/min. Agreement was assessed via Bland-Altman and error grid analyses, with a focus on the mean blood pressure (MBP) thresholds (≥ 65 mmHg and < 65 mmHg). Results: Among the 2,104 paired measurements, significant discrepancies were observed between the IABP and NIBP across all dose groups( p < 0.001). Discrepancies increased with higher norepinephrine doses, particularly at an MBP ≥ 65 mmHg, with biases of -3.89 mmHg (≤ 0.25 mcg/kg/min) and − 6.81 mmHg (≥ 0.50 mcg/kg/min). Error grid analysis revealed that 47.2% of MBP ≥ 65 mmHg measurements fell into clinically significant risk zones (B-E) at high doses. In patients aged > 65 years, significant differences were observed in all pressures ( p < 0.001), whereas younger patients showed discrepancies only in the mean and diastolic pressures. Conclusions: This study demonstrated significant discrepancies between IABP and NIBP in critically ill patients receiving norepinephrine, particularly at higher doses and in patients with MBP ≥ 65 mmHg. These findings highlight the limitations of NIBP monitoring in this population and support the importance of IABP monitoring in selected high-risk patients, while suggesting that NIBP monitoring may remain acceptable in more hemodynamically stable individuals. Applying these considerations in clinical practice may help optimize blood pressure monitoring strategies in the ICU.Keywords
This publication has 21 references indexed in Scilit:
- A comparison of invasive arterial blood pressure measurement with oscillometric non-invasive blood pressure measurement in patients with sepsisJournal of Anesthesia, 2024
- Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021Intensive Care Medicine, 2021
- Non-invasive oscillometric versus invasive arterial blood pressure measurements in critically ill patients: A post hoc analysis of a prospective observational studyJournal of Critical Care, 2020
- Correlation of Noninvasive Blood Pressure and Invasive Intra-arterial Blood Pressure in Patients Treated with Vasoactive Medications in a Neurocritical Care UnitNeurocritical Care, 2018
- Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care MedicineIntensive Care Medicine, 2014
- Noninvasive pulse wave analysis for the determination of central artery stiffnessMicrovascular Research, 2008
- Hemodynamic monitoring in shock and implications for managementIntensive Care Medicine, 2007
- Expert consensus document on arterial stiffness: methodological issues and clinical applicationsEuropean Heart Journal, 2006
- Effects of the antihypertensive agent, cicletanine, on noradrenaline release and vasoconstriction in perfused mesenteric artery of SHRBritish Journal of Pharmacology, 1998
- The Accuracy of Finapres™ Noninvasive Mean Arterial Pressure Measurements in Anesthetized PatientsAnesthesiology, 1991