Radiochromic film based dosimetry of image‐guidance procedures on different radiotherapy modalities
Open Access
- 8 November 2014
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 15 (6) , 229-239
Abstract
In this work we compare doses from imaging procedures performed on today's state‐of‐the‐art integrated imaging systems using a reference radiochromic film dosimetry system. Skin dose and dose profile measurements from different imaging systems were performed using radiochromic films at different anatomical sites on a humanoid RANDO phantom. EBT3 film was used to measure imaging doses from a TomoTherapy MVCT system, while XRQA2 film was used for dose measurements from kilovoltage imaging systems (CBCT on 21eX and TrueBeam Varian linear accelerators and CyberKnife stereoscopic orthogonal imagers). Maximum measured imaging doses in cGy at head, thorax, and pelvis regions were respectively 0.50, 1.01, and 4.91 for CBCT on 21eX, 0.38, 0.84, and 3.15 for CBCT on TrueBeam, 4.33, 3.86, and 6.50 for CyberKnife imagers, and 3.84, 1.90, and 2.09 for TomoTherapy MVCT. In addition, we have shown how an improved calibration system of XRQA2 film can achieve dose uncertainty level of better than 2% for doses above 0.25 cGy. In addition to simulation‐based studies in literature, this study provides the radiation oncology team with data necessary to aid in their decision about imaging frequency for image‐guided radiation therapy protocols.PACS number: 87.53.Bn, 87.55.Qr, 87.56.FcKeywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada (386009)
This publication has 38 references indexed in Scilit:
- Radiation exposure to patients from image guidance procedures and techniques to reduce the imaging doseRadiotherapy and Oncology, 2013
- IGRT induced dose burden for a variety of imaging protocols at two different anatomical sitesRadiotherapy and Oncology, 2012
- Inclusion of the dose from kilovoltage cone beam CT in the radiation therapy treatment plansMedical Physics, 2009
- Accurate patient dosimetry of kilovoltage cone‐beam CT in radiation therapyMedical Physics, 2008
- A (short) history of image-guided radiotherapyRadiotherapy and Oncology, 2008
- The management of imaging dose during image‐guided radiotherapy: Report of the AAPM Task Group 75Medical Physics, 2007
- Image-guided radiotherapy: rationale, benefits, and limitationsThe Lancet Oncology, 2006
- Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapyMedical Physics, 2006
- Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unitMedical Physics, 2005
- Flat-panel cone-beam computed tomography for image-guided radiation therapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2002