Comparison of contrast agents with high molarity and with weak protein binding in cerebral perfusion imaging at 3 T
- 30 September 2005
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 22 (5) , 597-604
Abstract
Purpose: To examine and compare properties of high‐molarity contrast agent gadobutrol (Gadovist) and weakly protein‐binding agent gadobenate‐dimeglumine (MultiHance®) in dynamic susceptibility contrast (DSC) perfusion imaging at 3 T.Materials and Methods: Sixteen healthy volunteers underwent three separate examinations with contrast agent doses of 0.1 and 0.2 mmol/kg body weight (bw) gadobutrol and 0.1 mmol/kg bw gadobenate‐dimeglumine. Maps of relative regional cerebral blood volume (rCBV) and blood flow (rCBF) were calculated using deconvolution based on singular value decomposition. Signal and concentration time curves, the concentration‐to‐noise ratio (SNRc), and gray matter (GM)‐to‐white matter (WM) rCBV and rCBF contrast and ratios were evaluated in a region of interest (ROI)‐based analysis. Image quality of calculated parametric maps was assessed in direct visual comparison and with respect to suitability for diagnostic purposes.Results: The contrast agents displayed very similar results in the 0.1 mmol/kg examinations, both with respect to the quantitative evaluation parameters and in the qualitative assessment of the calculated parametric maps. Maps from 0.2 mmol/kg examinations were rated as being superior in quality, but with respect to diagnostic suitability all contrast agents and doses yielded images of sufficient quality.Conclusion: At 3 T, a gadobutrol or gadobenate‐dimeglumine dose of 0.1 mmol/kg is sufficient for DSC magnetic resonance imaging (MRI) perfusion assessment. At the used small injection volumes, the tissue concentration curve was determined only by the gadolinium (Gd) dosage in mmol/kg, and the T2* relaxation effects of the two agents can be considered to be nearly identical in the applied gradient‐echo (GRE) sequence. J. Magn. Reson. Imaging 2005.Keywords
This publication has 22 references indexed in Scilit:
- Effects of echo time variation on perfusion assessment using dynamic susceptibility contrast MR imaging at 3 teslaMagnetic Resonance Imaging, 2004
- Tracer arrival timing‐insensitive technique for estimating flow in MR perfusion‐weighted imaging using singular value decomposition with a block‐circulant deconvolution matrixMagnetic Resonance in Medicine, 2003
- Dietary Caffeine Consumption and Withdrawal: Confounding Variables in Quantitative Cerebral Perfusion Studies?Radiology, 2003
- Safety of contrast-enhanced MR angiography employing gadobutrol 1.0 M as contrast materialEuropean Radiology, 2002
- Vergleich von MultiHance ® und Gadovist ® zur zerebralen MR-Perfusionsmessung bei gesunden ProbandenDer Radiologe, 2002
- Comparison of echo-planar sequences for perfusion-weighted MRI: which is best?Neuroradiology, 1998
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996
- Pharmacokinetics, Dose Proportionality, and Tolerability of Gadobutrol after Single Intravenous Injection in Healthy VolunteersInvestigative Radiology, 1994
- Perfusion imaging with NMR contrast agentsMagnetic Resonance in Medicine, 1990
- Dynamic imaging with lanthanide chelates in normal brain: Contrast due to magnetic susceptibility effectsMagnetic Resonance in Medicine, 1988