Radiation emission dose from patients administered 90Y-labelled radiopharmaceuticals: comparison of experimental measurements versus Monte Carlo simulation
Authors:
- Sergio Lo MeoSMSergio Lo Meo
- Gianfranco CicoriaGCGianfranco Cicoria
- Giancarlo MontiniGMGiancarlo Montini
- Carlo BergaminiCBCarlo Bergamini
- Francesco CampanellaFCFrancesco Campanella
- Davide PancaldiDPDavide Pancaldi
- Antonio Sabatino PanebiancoAPAntonio Sabatino Panebianco
- Domenico RubelloDRDomenico Rubello
- Mario MarengoMMMario Marengo
- 1 December 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 29 (12) , 1100-1105
Abstract
To estimate the radiation dose delivered from patients injected with yttrium-90 (Y)-labelled tiuxetan (Zevalin) to parents and the general population, comparing different techniques. The radiation dose delivered from a group of eight patients injected with Y-Zevalin to treat recurrent lymphoma was measured. The data obtained with the Monte Carlo simulation test were compared with the experimental measurements obtained with an ionization chamber detector and with a crystal NaI(Tl) detector. A good correlation was found between the Monte Carlo simulation test and the ionization chamber detector results: the air kerma dose rate was 4.2+/-0.1 and 4.4+/-0.8 microGy/h, respectively (r=0.9, P<0.01). Moreover, more than 99.7% of the air kerma dose rate measured with the ionization chamber detector was because of the contribution of electrons, whereas the contribution of photons was less than 0.3%. In contrast, the air kerma dose rate measured with the crystal NaI(Tl) detector was significantly lower (0.76+0.12 microGy/h) in comparison with the Monte Carlo simulation test. This underestimation was related to the limited crystal NaI(Tl) detector response to low energy rates at variance with the ionization chamber detector. The effective radiation dose released by patients treated with Y-labelled tiuxetan to parents and the general population was approximately 0.1 mSv per treatment cycle. Using the Monte Carlo model as a benchmark to compare the experimental measurements obtained by the two different detectors, we found that the ionizing chamber detector was more accurate than the crystal Na(Tl) detector for measuring the exposure radiation dose delivered from patients administered with Y-labelled radiopharmaceuticals. Moreover, the effective radiation dose released by these patients to their parents and the general population is significantly lower than the value recommended by international reports and regulations.Keywords
This publication has 10 references indexed in Scilit:
- Application of Three-Class ROC Analysis to Task-Based Image Quality Assessment of Simultaneous Dual-Isotope Myocardial Perfusion SPECT (MPS)IEEE Transactions on Medical Imaging, 2008
- Comparison of Residence Time Estimation Methods for Radioimmunotherapy Dosimetry and Treatment Planning—Monte Carlo Simulation StudiesIEEE Transactions on Medical Imaging, 2008
- A phase 2 trial of fludarabine and mitoxantrone chemotherapy followed by yttrium‐90 ibritumomab tiuxetan for patients with previously untreated, indolent, nonfollicular, non‐Hodgkin lymphomaCancer, 2008
- Monte Carlo investigations of megavoltage cone-beam CT using thick, segmented scintillating detectors for soft tissue visualizationMedical Physics, 2007
- Evaluation of reconstruction techniques for lung single photon emission tomography: A Monte Carlo studyNuclear Medicine Communications, 2007
- 90Y-Ibritumomab tiuxetan: new drug, interesting concept, and encouraging in practiceNuclear Medicine Communications, 2006
- Geant4 developments and applicationsIEEE Transactions on Nuclear Science, 2006
- Radiolabeled antibody therapy in non-Hodgkins lymphoma: radiation protection, isotope comparisons and quality of life issuesCancer Treatment Reviews, 2004
- Dosimetry characterization of 32P intravascular brachytherapy source wires using Monte Carlo codesPENELOPEandGEANT4Medical Physics, 2004
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003