Combining Zonal Refractive and Diffractive Aspheric Multifocal Intraocular Lenses
Authors:
- Gonzalo MuñozGMGonzalo Muñoz
- César Albarrán-DiegoCACésar Albarrán-Diego
- Jaime JavaloyJJJaime Javaloy
- Hani F. SaklaHSHani F. Sakla
- Alejandro CerviñoAlejandro Cerviño
- 1 March 2012
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 28 (3) , 174-181
Abstract
PURPOSE: To assess visual performance with the combination of a zonal refractive aspheric multifocal intraocular lens (MIOL) (Lentis Mplus, Oculentis GmbH) and a diffractive aspheric MIOL (Acri.Lisa 366, Acri.Tech GmbH). METHODS: This prospective interventional cohort study comprised 80 eyes from 40 cataract patients (mean age: 65.5±7.3 years) who underwent implantation of the Lentis Mplus MIOL in one eye and Acri.Lisa 366 MIOL in the fellow eye. The main outcome measures were refraction; monocular and binocular uncorrected and corrected distance, intermediate, and near visual acuities; monocular and binocular defocus curves; binocular photopic contrast sensitivity function compared to a monofocal intraocular lens (IOL) control group (40 age-matched pseudophakic patients implanted with the AR-40e [Abbott Medical Optics]); and quality of vision questionnaire. RESULTS: Binocular uncorrected visual acuities were 0.12 logMAR (0.76 decimal) or better at all distances measured between 6 m and 33 cm. The Lentis Mplus provided statistically significant better vision than the Acri.Lisa at distances between 2 m and 40 cm, and the Acri.Lisa provided statistically significant better vision than the Lentis Mplus at 33 cm. Binocular defocus curve showed little drop-off at intermediate distances. Photopic contrast sensitivity function for distance and near were similar to the monofocal IOL control group except for higher frequencies. Moderate glare (15%), night vision problems (12.5%), and halos (10%) were reported. Complete independence of spectacles was achieved by 92.5% of patients. CONCLUSIONS: The combination of zonal refractive aspheric and diffractive aspheric MIOLs resulted in excellent uncorrected binocular distance, intermediate, and near vision, with low incidence of significant photic phenomena and high patient satisfaction.Keywords
This publication has 29 references indexed in Scilit:
- Visual and Optical Performance With Two Different Diffractive Multifocal Intraocular Lenses Compared to a Monofocal LensJournal of Refractive Surgery, 2011
- Visual Acuity Outcomes With SA60D3, SN60D3, and ZM900 Multifocal IOL Implantation After PhacoemulsificationJournal of Refractive Surgery, 2010
- Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a +3.0 D additionJournal of Cataract & Refractive Surgery, 2009
- Dissatisfaction after multifocal intraocular lens implantationJournal of Cataract & Refractive Surgery, 2009
- Optical Performance in ReZoom and Array Multifocal Intraocular Lenses In VitroJournal of Refractive Surgery, 2009
- Prospective functional and clinical comparison of bilateral ReZoom and ReSTOR intraocular lenses in patients 70 years or youngerJournal of Cataract & Refractive Surgery, 2008
- Optical performance of monofocal and multifocal intraocular lenses in the human eyeJournal of Cataract & Refractive Surgery, 2008
- Prospective study of the Acri.LISA bifocal intraocular lensJournal of Cataract & Refractive Surgery, 2007
- Visual Performance of Patients with Bilateral vs Combination Crystalens, ReZoom, and ReSTOR Intraocular Lens ImplantsAmerican Journal of Ophthalmology, 2007
- Modulation transfer function and pupil size in multifocal and monofocal intraocular lenses in vitroJournal of Cataract & Refractive Surgery, 2005