Phasor-Based Single-Phase Auto-Reclosing Scheme for Non-Compensated Transmission Lines
- 1 February 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (1) , 219-229
Abstract
An approach to detect the secondary arc extinction is proposed here for single-phase auto-reclosing of non-compensated transmission lines. It consists on the analysis of the line side voltage phasors in the modal domain to safely and rapidly identify the presence and the extinction of secondary arc in the line. The procedure can also determine the arc re-ignition if it occurs during the line dead time. Since the proposed approach requires only the voltage phasors at one line terminal, it can be easily implemented in existing Intelligent Electronic Devices (IEDs) with no additional hardware or equipment requirement. Data from the Brazilian Power Grid were used to generate the case studies through the Electromagnetic Transients Program (EMTP). Moreover, field recordings were used to validate the proposed approach. A qualitative comparison with existing methods was accomplished and the obtained results reveal the proposed scheme efficiency, reliability and robustness.Keywords
This publication has 50 references indexed in Scilit:
- Design of a novel phasor measurement unit-based transmission line auto reclosing schemeIET Generation, Transmission & Distribution, 2011
- Adaptive single pole auto-reclosing using discrete wavelet transformEuropean Transactions on Electrical Power, 2010
- New approach to adaptive single pole auto-reclosing of power transmission linesIET Generation, Transmission & Distribution, 2010
- Phasor estimation technique to reduce the impact of coupling capacitor voltage transformer transientsIET Generation, Transmission & Distribution, 2008
- A Novel Adaptive Single-Phase Reclosure Scheme Using Dual-Window Transient Energy Ratio and Mathematical MorphologyIEEE Transactions on Power Delivery, 2006
- New One Terminal Digital Algorithm for Adaptive Reclosing and Fault Distance Calculation on Transmission LinesIEEE Transactions on Power Delivery, 2006
- Determinination of the ARC extinction time on power lines using voltage signalsEuropean Transactions on Electrical Power, 2002
- Design and implementation of an adapative single pole autoreclosure technique for transmission lines using artificial neural networksIEEE Transactions on Power Delivery, 1996
- Single phase tripping and auto reclosing of transmission lines-IEEE Committee ReportIEEE Transactions on Power Delivery, 1992
- Digital simulation of fault arcs in power systemsEuropean Transactions on Electrical Power, 1991