Optimal Nasopharyngeal Temperature Probe Placement
Authors:
- Hyungsun LimHLHyungsun Lim
- Kyung-Geun SonKSKyung-Geun Son
- Seonghoon KoSKSeonghoon Ko
- 1 October 2014
- journal article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 119 (4) , 875-879
Abstract
He nasopharyngeal mucosa is in closest proximity to the internal carotid artery (ICA) and (2) to evaluate the tip position of nasopharyngeal temperature probes that were placed by anesthesiology residents and nurse anesthetists. METHODS: In the first phase of the study, we reviewed enhanced axial computed tomography images of 100 patients to determine where the nasopharyngeal mucosa was in closest proximity to the left or the right ICA. The distance from this point to the nares was then measured in the sagittal image. In the second phase of the study, nasendoscopy was used to evaluate the positioning of nasopharyngeal temperature probes placed by anesthesiology residents (244 patients) or nurse anesthetists (116 patients). Malpositioned probes were repositioned to an optimal location, and the temperature differences were recorded. RESULTS: In the computed tomography images, the mucosa in closest proximity to the ICA was in the upper, mid-, and lower nasopharynx in 60%, 38%, and 2% of patients, respectively. The average distances between the ICA and the nasopharyngeal mucosa in the upper portion were significantly shorter than those in the lower portion (female: 9.4 vs 16.8 mm, P < 0.001; male: 12.4 vs 18.8 mm, P < 0.001). The average distances (95% prediction interval) from the nares to the upper portion of the nasopharynx through the inferior meatus were 9.1 (8.1–10.2) cm in females and 9.7 (8.6–10.8) cm in males. Temperature probes were correctly positioned in the upper or mid-nasopharynx by residents and nurses in 43% (95% confidence interval [CI], 37%–49%) and 41% (95% CI, 36%–50%), respectively. When the probe was inadvertently placed in the nasal cavity, the median (95% CI) temperature difference from the upper nasopharynx was 0.2°C (0.15°C–0.25°C). CONCLUSIONS: The closest portion of the nasopharyngeal mucosa to the ICA is within the upper or mid-nasopharynx. The depth from the nares to the upper one-third of the nasopharynx is approximately 10 cm. Less than half of nasopharyngeal temperature probes placed blindly by practitioners were optimally positioned....Keywords
This publication has 14 references indexed in Scilit:
- Perioperative Maintenance of Normothermia Reduces the Incidence of Morbid Cardiac EventsJAMA, 1997
- Perioperative Normothermia to Reduce the Incidence of Surgical-Wound Infection and Shorten HospitalizationThe New England journal of medicine, 1996
- Mild hypothermia increases blood loss and transfusion requirements during total hip arthroplastyThe Lancet, 1996
- Unintentional Hypothermia Is Associated with Postoperative Myocardial IschemiaAnesthesiology, 1993
- Central Thermoregulatory Inhibition by General AnesthesiaAnesthesiology, 1991
- Sweating Threshold During Isoflurane Anesthesia in HumansAnesthesia & Analgesia, 1991
- The Thermoregulatory Threshold in Infants and Children Anesthetized with Isoflurane and Caudal BupivacaineAnesthesiology, 1990
- Placement of esophageal stethoscope by acoustic criteria does not consistently yield an optimal location for the monitoring of core temperatureJournal of Clinical Monitoring and Computing, 1990
- The Thermoregulatory Threshold is Inversely Proportional to Isoflurane ConcentrationAnesthesiology, 1990
- The Thermoregulatory Threshold in Humans during Nitrous Oxide-Fentanyl AnesthesiaAnesthesiology, 1988