High frequency modeling of a shielded four-core low voltage underground power cable
Authors:
- 9 April 2015
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 22 (2) , 649-656
Abstract
Underground low voltage (LV) power cables have a long life span, and so far minimum effort was put in methods for condition assessment. However, a slow but steady increase in the amount of faults is being observed and future de-central power generation may further put pressure on the reliability of the LV grid. Therefore, condition monitoring for LV cable systems is under investigation. With the occurrence of intermittent faults, fast transients from discharges may be observed before an outage occurs. To estimate if such signals are measurable, a model of the cable valid up to 50 MHz was derived. Numerical simulations have been used to obtain the parameters of the multi-conductor transmission line model, with special consideration of the copper screen configuration. Measurements on a 60 m cable segment have been performed to verify the model, showing good agreement. This model will be used to investigate signal propagation through a LV grid with focus on the feasibility to base LV condition monitoring on signals which may originate from upcoming cable faults.Keywords
This publication has 12 references indexed in Scilit:
- Estimation of multi‐conductor powerline cable parameters for the modelling of transfer characteristicsIET Science, Measurement & Technology, 2014
- Factors influencing broadband transmission characteristics of underground low-voltage distribution networksIET Communications, 2012
- Transfer Characteristics Modeling of Four-Conductor Cables in Power-Line CommunicationsIEEE Transactions on Power Delivery, 2011
- Transmission Characteristics of Low-Voltage Distribution Networks in China Under the Smart Grids EnvironmentIEEE Transactions on Power Delivery, 2010
- Measurement of transmission line parameters of three-core power cables with common earth screenIET Science, Measurement & Technology, 2010
- Basic Principles Concerning the Experimental Evaluation of the Frequency-Dependent Parameters of Shielded and Unshielded Three-Phase Symmetric CablesIEEE Transactions on Power Delivery, 2010
- Skin effect and dielectric loss models of power cablesIEEE Transactions on Dielectrics and Electrical Insulation, 2009
- High Frequency Loss From Neutral Wire-Shield Interaction of Shielded Power CableIEEE Transactions on Power Delivery, 2008
- Electrical Parameters of Low-Voltage Power Distribution Cables Used for Power-Line CommunicationsIEEE Transactions on Power Delivery, 2007
- Comparing two measurement techniques for high frequency characterization of power cable semiconducting and insulating materialsIEEE Transactions on Dielectrics and Electrical Insulation, 2006