Systematic evaluation of repeatability of IR-MALDESI-MS and normalization strategies for correcting the analytical variation and improving image quality
- 25 June 2019
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 411 (22) , 5729-5743
Abstract
Mass spectrometry imaging is a powerful tool widely used in biological, clinical, and forensic research, but its often poor repeatability limits its application for quantitative and large-scale analysis. A systematic evaluation of infrared matrix-assisted laser desorption electrospray ionization mass spectrometry (IR-MALDESI-MS) repeatability in absolute ion abundances during short- and long-term experiments was carried out on liver slices from the same rat with minimal biological variability to be expected. Results of median %RSDs ranging from 14 to 45, pooled %RMADs ranging from 11 to 33, and Pearson correlation coefficients ranging from 0.83 to 1.00 demonstrated an acceptable repeatability of IR-MALDESI-MS. Normalization is commonly applied for the purpose of accounting for analytical variability of spectra generated from different runs so as to reveal real biological differences. Nine data normalization strategies were performed on the rat liver data sets to examine their effects on reducing analytical variation, and further on a hen ovary data set containing more morphological features for the investigation of their impact on ion images. Results demonstrated that the majority of normalization approaches benefit data quality to some extent, and local normalization methods significantly outperform their global counterparts, resulting in a reduction of median %RSD up to 22. Local median normalization was found to be promisingly robust for both homogeneous and heterogeneous samples.Keywords
Funding Information
- National Institute of General Medical Sciences (R01GM087964)
This publication has 41 references indexed in Scilit:
- Robust Data Processing and Normalization Strategy for MALDI Mass Spectrometric ImagingAnalytical Chemistry, 2012
- Normalization in MALDI-TOF imaging datasets of proteins: practical considerationsAnalytical and Bioanalytical Chemistry, 2011
- Study of the ionization mechanism in hybrid laser based desorption techniquesThe Analyst, 2010
- ProteoWizard: open source software for rapid proteomics tools developmentBioinformatics, 2008
- Comparison of normalisation methods for surface-enhanced laser desorption and ionisation (SELDI) time-of-flight (TOF) mass spectrometry dataBMC Bioinformatics, 2008
- Reproducibility in Protein Profiling by MALDI-TOF Mass SpectrometryClinical Chemistry, 2007
- Processing MALDI mass spectra to improve mass spectral direct tissue analysisInternational Journal of Mass Spectrometry, 2007
- Normalization of cDNA microarray dataMethods, 2003
- Exploration, normalization, and summaries of high density oligonucleotide array probe level dataBiostatistics, 2003
- Improvement of signal reproducibility and matrix/comatrix effects in MALDI analysisAnalytical Chemistry, 1995