Background: To accelerate progress toward Family Planning 2020 (FP2020) goals, the government of India focused on improving the quality of intrauterine device (IUD) services. EngenderHealth, an international sexual and reproductive health and rights organization, has been supporting the governments of Gujarat and Rajasthan since 2014 through the Expanding Access to IUD Services in India (EAISI) project by building the capacity of service providers, monitoring compliance with standard practices, and strengthening health systems. This study sought to assess whether EAISI-trained providers offer higher quality IUD services than non-EAISI-trained providers, as indicated by a reduction in confirmed IUD complications. Methods: The study team conducted an analytical cross-sectional study of secondary data collected from follow-up registers at 176 intervention facilities (38 in Gujarat and 138 in Rajasthan) during Phase I of the EAISI project. The analysis included follow-up clients who returned to the same facility between April 2018 and March 2019. We performed a multivariate logistic regression to determine factors associated with IUD complications. Results: During the period of assessment, 56,733 clients received IUD insertions, and 10,747 (18.9%) clients returned for follow-up services. Of the returning clients, 49.4% (N=5,305) had received IUDs from EAISI-trained providers, while 50.6% (N=5,442) had received IUDs from non-EAISI-trained providers. A total of 4.0% (N=432) of all returning clients experienced complications (expulsion: 1.3%, missing strings: 1.7%, infection: 1.1%). Clients who received IUDs from non-EAISI-trained providers were 55.5% more likely (95% CI [26.2%, 91.5%], p<0.0005) to have experienced complications than clients who received insertions from EAISI-trained providers. The type of IUD, the timing of the insertion, and the timing of the follow-up visit also affected complication prevalence. Conclusion: Our findings indicate that intensive, practical clinical skills training for IUD insertion can reduce the prevalence of complications.Keywords
Funding Information
- Bill and Melinda Gates Foundation (OPP1181398)
This publication has 18 references indexed in Scilit:
- Association of Age and Parity With Intrauterine Device ExpulsionObstetrics & Gynecology, 2014
- Understanding benefits and addressing misperceptions and barriers to intrauterine device access among populations in the United StatesPatient Preference and Adherence, 2014
- Postplacental intrauterine device insertion at a teaching hospitalContraception, 2014
- Evidence-Based Selection of Candidates for the Levonorgestrel Intrauterine Device (IUD)The Journal of the American Board of Family Medicine, 2014
- Health Care Provider Attitudes and Practices Related to Intrauterine Devices for Nulliparous WomenObstetrics & Gynecology, 2012
- Immediate postplacental insertion of an intrauterine contraceptive device during cesarean sectionContraception, 2011
- Complications among adolescents using copper intrauterine contraceptive devicesInternational Journal of Gynecology & Obstetrics, 2011
- Risk of Uterine Rupture Associated With an Interdelivery Interval Between 18 and 24 MonthsObstetrics & Gynecology, 2010
- Risk factors for IUD failure: results of a large multicentre case-control studyHuman Reproduction, 2006