Transscleral Fixation by Injector Implantation of a Foldable Intraocular Lens
Authors:
- Sung Yong ParkSPSung Yong Park
- Hae Jung SunHSHae Jung Sun
- 1 March 2010
- journal article
- research article
- Published by SLACK, Inc. in Ophthalmic Surgery, Lasers and Imaging Retina
- Vol. 41 (2) , 272-275
Abstract
Scleral fixation of a foldable intraocular lens (IOL) was performed in 17 eyes of 17 patients using a new small incision technique with injector implantation. All eyes were implanted with a hydrophobic acrylic three-piece IOL, either with phacoemulsification surgery or secondarily. No cases of intraoperative or postoperative complications were observed. The operation time required for scleral fixation only was less than 30 minutes in all cases. Scleral fixation of foldable IOLs using a self-sealing tunnel incision and injector technique minimizes intraoperative hypotony and related complications such as suprachoroidal hemorrhage. Furthermore, this technique saves surgery time and the sutureless technique used for most patients can reduce postoperative astigmatism. [Ophthalmic Surg Lasers Imaging 2010;41:272–275.]Keywords
This publication has 6 references indexed in Scilit:
- Transscleral fixation of foldable intraocular lensesJournal of Cataract & Refractive Surgery, 2004
- Transscleral fixation of a foldable intraocular lens in aphakic vitrectomized eyesJournal of Cataract & Refractive Surgery, 2003
- Scleral Fixation of a Foldable Intraocular LensOphthalmic Surgery, Lasers and Imaging Retina, 2002
- An Improved Technique for Management of Dislocated Posterior Chamber ImplantsOphthalmology, 1992
- Ab Externo Sulcus FixationOphthalmic Surgery, Lasers and Imaging Retina, 1991
- Anatomic Study of Transsclerally Sutured Intraocular Lens ImplantationAmerican Journal of Ophthalmology, 1989