Silicon wafers used as starting materials are significantly different in MOS‐LSIs and power devices, because each device requires a specific structure. For power devices, FZ wafers or epitaxial wafers with a thick epitaxial layer are widely used. Epitaxial wafers are advantageous with respect to low breakdown voltage devices, and FZ wafers are advantageous for high breakdown voltage devices. The influence of COPs formed during CZ crystal growth on highly miniaturized MOS‐LSIs is significant; however, COPs do not pose a problem to power devices prepared from FZ or epitaxial wafers. BMDs and slip dislocations have caused device failures on power devices where the device operation layer is deep and the process temperature is high. On the other hand, misfit dislocations which are generated with high concentration do not introduce device failures. Failure due to physical contamination is observed when Fe has introduced a failure to the power device. Cu/pit failures occur due to chemical contamination by Cu only for more highly miniaturized MOS‐LSIs, but are not a problem for power devices whose miniaturization level is not required as that for MOS‐LSIs.