Air exchange in tall apartment buildings is critical in controlling indoor environments in urban settings. Airtightness is relevant to energy efficiency, thermal comfort and air quality experienced by urban dwellers who spend much of their time indoors. While many air change measurements have been made in residential homes, fewer are available for high-rise apartments. The blower-door and CO2 exchange methods were used to measure air change in some Hong Kong apartment buildings, for comparison with those from other parts of the world. Hong Kong apartments are often small and typical rented apartments show a median of seven air changes per hour under a 50 Pa pressure difference, similar to Mediterranean houses, though much greater than the airtight buildings of Northern Europe. Extrapolation of blower-door measurements made at 50 Pa to the natural pressure difference measured for individual Hong Kong apartments provides an approximation (within 8%) of the natural air change rate measured with a tracer. Air flow is a function of the pressure difference ∆Pnf and the exponent n was found close to the typical 0.6. There was a positive relationship between air permeability and construction age, but some of this also seems to reflect varying levels of maintenance by the building management companies. The median exchange in the apartments under naturally ventilated conditions was 0.26 h−1, not atypical of some houses on the US West Coast.Keywords
Funding Information
- Research Grants Council of the Hong Kong (9042397)
This publication has 24 references indexed in Scilit:
- Indoor air quality in substandard housing in Hong KongSustainable Cities and Society, 2019
- Assessment of personal integrated exposure to fine particulate matter of urban residents in Hong KongJournal of the Air & Waste Management Association, 2018
- A comprehensive review on passive design approaches in green building rating toolsRenewable and Sustainable Energy Reviews, 2015
- Air Leakage Characteristics and Leakage Distribution of Dwellings in High-rise Residential Buildings in KoreaJournal of Asian Architecture and Building Engineering, 2013
- Measured air tightness performance of residential buildings in North China and its influence on district space heating energy useEnergy and Buildings, 2012
- Experimental analysis of air tightness in Mediterranean buildings using the fan pressurization methodBuilding and Environment, 2012
- Review of relationship between indoor and outdoor particles: I/O ratio, infiltration factor and penetration factorAtmospheric Environment, 2011
- Building leakage, infiltration, and energy performance analyses for Finnish detached housesBuilding and Environment, 2009
- Energy-efficient houses built according to the energy performance requirements introduced in Denmark in 2006Energy and Buildings, 2007