An Automatic Algorithm Based on Morphological Stability During Fast Ventricular Arrhythmias Predicts Successful Antitachycardia Pacing in ICD Patients: A Multicenter Study
- 4 May 2016
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 39 (7) , 633-641
Abstract
Different types of ventricular arrhythmias (monomorphic VT, polymorphic VT or ventricular fibrillation) can be detected by implantable cardiac defibrillators in fast VT zone. The efficacy of antitachycardia pacing (ATP) depends on the type of the treated arrhythmia. We hypothesized that an automatic algorithm based on morphological affinity of ICD far-field electrograms during tachycardia can predict ATP success and the need of shock.The algorithm was evaluated on ventricular arrhythmias recorded in Carelink ICD remote monitoring system. Patients were selected if first ATP programmed was a burst of 8 pulses at 88% coupling interval and if a far-field electrogram was available. The algorithm calculated a stability coefficient (SC) for all their stored ATP-treated fast VA episodes (LC 200-300 msec.), analyzing the morphology homogeneity of the last 8 recorded far-field electrograms before ventricular arrhythmias detection.Inclusion criteria were fulfilled by 717 patients from 29 centers. Three hundred and twenty fast VA were recorded in 103 patients. A higher SC was observed in episodes terminated with the first-ATP [0.78 (0.72-0.84) vs 0.74 (0.60-0.84); P = 0.006]. These differences were especially marked among the 62 episodes of very fast VA (CL ≤250 msec.) [0.77 (0.74-0.85) vs 0.64 (0.51-0.8); P = 0.006]. In the multivariate analysis, a SC>70% was independently associated with a higher likelihood of first-ATP success (OR = 2.5; [95% CI = 1.4-4.5], P = 0.001) and a lower need of shock (OR = 0.37; [95% CI = 0.2-0.7], P = 0.002).This automatic algorithm (Stability coefficient) shows that ATP therapy response can be predicted in fast ventricular arrhythmias through morphology evaluation. This article is protected by copyright. All rights reserved.Keywords
Funding Information
- Medtronic Iberica
This publication has 18 references indexed in Scilit:
- Reduction in Inappropriate Therapy and Mortality through ICD ProgrammingNew England Journal of Medicine, 2012
- Long-Term Outcome After ICD and CRT Implantation and Influence of Remote Device Follow-UpCirculation, 2010
- Combining Shock Reduction Strategies to Enhance ICD Therapy: A Role for Computer ModelingJournal of Cardiovascular Electrophysiology, 2010
- Influence of beta-blocker therapy on antitachycardia pacing effectiveness for monomorphic ventricular tachycardias occurring in implantable cardioverter-defibrillator patients: a dose-dependent effectEP Europace, 2010
- Prospective multicenter randomized trial of fast ventricular tachycardia termination by prolonged versus conventional anti-tachyarrhythmia burst pacing in implantable cardioverter-defibrillator patients-Atp DeliVery for pAiNless ICD thErapy (ADVANCE-D) Trial resultsJournal of Interventional Cardiac Electrophysiology, 2010
- Prognostic Importance of Defibrillator Shocks in Patients with Heart FailureNew England Journal of Medicine, 2008
- Improving SVT Discrimination in Single‐Chamber ICDs: A New Electrogram Morphology‐Based AlgorithmJournal of Cardiovascular Electrophysiology, 2006
- Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart FailureNew England Journal of Medicine, 2005
- Prospective Randomized Multicenter Trial of Empirical Antitachycardia Pacing Versus Shocks for Spontaneous Rapid Ventricular Tachycardia in Patients With Implantable Cardioverter-DefibrillatorsCirculation, 2004
- Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection FractionNew England Journal of Medicine, 2002