High-Grade Isthmic Dysplastic Spondylolisthesis
Authors:
- 15 March 2005
- journal article
- evaluation and-management
- Published by Wolters Kluwer Health in Spine
- Vol. 30 (Supplement) , S42-S48
Abstract
Study Design. A prospective single arm cohort. Objective. To study the results of distraction reduction of high-grade isthmic dysplastic spondylolisthesis with posterior lumbar interbody fusion and posterior compression in a consecutive, prospectively collected series of adolescent patients. Summary of Background Data. High-grade isthmic dysplastic spondylolisthesis has been associated with a high complication and failure rate regardless of the method of surgical treatment, including in situ fusion, cast correction and fusion, anterior fusion, posterior instrumented fusion, and combination procedures. Methods. A total of 18 adolescents with the diagnosis and a minimum 50% slip underwent the procedure of Gill decompression, temporary distraction with reduction of the deformity, complete lumbosacral discectomy, posterior lumbar interbody fusion with Harm’s cage and autogenous iliac graft, and posterior monosegmental compression instrumentation with pedicular fixation. Results. Follow-up ranged from 2.3 to 5 years. Slip improved from 77% to 13% and slip angle from 35° to 3.8° initially and 4.3° at final follow-up. One patient had loss of 16° of slip angle but achieved arthrodesis. Sacral inclination improved from 28° to 39°. There were no neurologic or infectious complications. There were no overt instrumentation failures. Arthrodesis was achieved in every instance. Two patients had structural complications, neither of which underwent reoperation. Conclusions. The index procedure provided near-anatomic correction of high-grade spondylolisthesis, which is maintained at a minimum 2-year follow-up without significant complications. There were two structural complications. Anterior column structural support and posterior compressive instrumentation help restore the necessary biomechanics to allow clinical fusion and success. This series has led the senior author to evolve his technique tooften include caudad fixation to the pelvis and/or cephalad fixation to L4.Keywords
This publication has 22 references indexed in Scilit:
- Biomechanical Comparison of Lumbosacral Fixation Techniques in a Calf Spine ModelSpine, 2002
- Complications in the Surgical Treatment of Pediatric High-Grade, Isthmic Dysplastic SpondylolisthesisSpine, 1999
- Surgical Management of Severe Spondylolisthesis in Children and AdolescentsSpine, 1997
- Reduction of High-grade Spondylolisthesis Using Edwards InstrumentationSpine, 1996
- Stimulus-Evoked EMG Monitoring During Transpedicular Lumbosacral Spine InstrumentationSpine, 1994
- Results of In Situ Fusion for Isthmic SpondylolisthesisJournal of Spinal Disorders, 1992
- Reduction of High-Grade Slips (Grades Hi—V) with VSP® InstrumentationSpine, 1991
- Surgical Treatment of Isthmic Lumbosacral SpondylolisthesisSpine, 1989
- Closed Reduction of SpondylolisthesisSpine, 1988
- Distraction Rod Instrumentation with Posterolateral Fusion in Isthmic SpondylolisthesisSpine, 1985